中频均匀磁场暴露下人脑皮层电刺激评估的数值研究
Numerical Study on Human Brain Cortical Electrostimulation Assessment During Uniform Magnetic Field Exposure at Intermediate Frequencies
AI总结:
本研究针对中频磁场暴露下人脑皮层电刺激评估问题,采用多尺度计算建模整合神经元与真实头部模型,证实现有保护限值保守性及受试者变异性,为修订电磁安全指南提供依据。
摘要:
目的:国际指南和标准已制定电磁场暴露的人体保护允许限值,以防止最敏感身体部位因电刺激产生不良健康影响。在中频范围(300Hz至100kHz)内,最敏感部位为周围神经系统(PNS);而在较低频率下,则为中枢神经系统(CNS)。然而,考虑到头部电磁暴露时脑组织的重要性,需重新评估中频范围内针对CNS电刺激的保护限值。本研究旨在推导CNS皮层刺激水平,以评估对现有保护限值的符合性。方法:采用多尺度计算建模,将单个神经元整合到真实解剖头部模型中,以评估神经元刺激阈值。在3个人体头部模型中,对运动皮层内的5种不同可兴奋膜模型进行了检验,这是迄今为止最全面、最广泛的评估。结果:现有保护限值被证实具有保守性,在钳位边界条件下,仅0.02%的轴突不符合要求;在密封边界条件下,该比例为2.4%。研究强调了受试者间存在显著变异性(平均阈值差异高达600%),并阐明了神经兴奋模型对允许水平评估的影响。结论:现有电场限值对于中频范围内的CNS电刺激具有保守性,但在较高频率下安全裕度降低,需进一步评估。影响:本研究的发现和方法为修订电磁安全暴露指南提供了理论依据和有价值的见解。
英文摘要:
Objectives: Permissible limits have been established by international guidelines and standards for human protection to electromagnetic field exposure to prevent adverse health effects stemming from electrostimulation in the most sensitive body part. That is the peripheral nervous system (PNS) in the intermediate frequency range (300 Hz to 100 kHz) and the central nervous system (CNS) at lower frequencies. However, there is a need to reevaluate protection limits against CNS electrostimulation in the intermediate frequency range, considering the importance of brain tissues during electromagnetic head exposure. This study aims to derive the level of CNS cortical stimulation to evaluate compliance with existing protection limits. Method: Multi-scale computation modelling was used to evaluate neuron stimulation thresholds by integrating individual neurons into realistic anatomical head models. Five different excitable membrane models within the motor cortex were examined across three human head models, providing the most comprehensive and extensive evaluation to date. Results: Current protection limits are confirmed as conservative, with non-compliance observed in only 0.02% and 2.4% of axons under clamped and sealed boundary conditions, respectively. The study highlights significant intersubject variability (up to 600% mean threshold) and clarifies the influence of neural excitation models on permissible level assessments. Conclusion: Current electric field limits are conservative for CNS electrostimulation in the intermediate frequencies range, but the margin of safety decreases at higher frequencies, warranting further evaluation. Impact: The findings and methodology contribute to the rationale and provide valuable insights for revising electromagnetic safety exposure guidelines.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。