重新审视用于识别运动神经元放电活动的卷积盲源分离:从理论到实践
Revisiting convolutive blind source separation for identifying spiking motor neuron activity: From theory to practice
AI总结:
本文从理论层面重新审视卷积盲源分离在运动神经元识别中的应用,提出可预测逆解存在性并量化估计误差的框架,通过仿真揭示MUAP相似性、目标函数选择及源质量指标等因素对检测性能的影响,为算法开发和临床应用提供理论指导。
摘要:
研究目的:通过分解来自肌肉的信号(例如表面肌电图(EMG)或超声),可以非侵入性地识别运动神经元(MN)的活动。MN识别的理论背景是卷积盲源分离(cBSS),目前已开发并验证了多种算法。然而,逆解的存在性与可辨识性以及相应的估计误差尚未被充分理解。此外,选择合适参数的指导原则往往建立在经验观察之上,这限制了向临床应用和其他模态的转化。研究方法:我们重新审视了用于MN识别的cBSS模型,为其补充了新的理论见解,并推导出一个能够预测逆解存在性的框架。该框架允许量化由于运动单位动作电位(MUAP)的不完全反演、噪声源以及逆问题病态性所导致的估计误差。为了弥合理论与实践之间的差距,我们使用了计算机模拟。主要结果:(1)提高MUAP的相似性或脉冲序列之间的相关性会增加检测高幅值MU的偏差。(2)最优目标函数取决于预期脉冲幅值、脉冲幅值统计特性以及背景脉冲的幅值。(3)在MUAP非平稳的情况下,MN检测存在一定的容错空间。(4)与先前的指导原则相反,MUAP持续时间与扩展因子之间没有关联。(5)源质量指标(如轮廓系数(SIL)或脉冲噪声比(PNR))与源的目标函数输出高度相关。(6)SIL优于PNR。研究意义:这些发现将指导针对MN识别和临床应用转化而定制的cBSS算法开发。
英文摘要:
Objective: Identifying the activity of motor neurons (MNs) non-invasively is possible by decomposing signals from muscles, e.g., surface electromyography (EMG) or ultrasound. The theoretical background of MN identification is convolutive blind source separation (cBSS), and different algorithms have been developed and validated. Yet, the existence and identifiability of inverse solutions and the corresponding estimation errors are not fully understood. Further, the guidelines for selecting appropriate parameters are often built on empirical observations, limiting the translation to clinical applications and other modalities. Approach: We revisited the cBSS model for MN identification, augmented it with new theoretical insights and derived a framework that can predict the existence of inverse solutions. This framework allows the quantification of estimation errors due to the imperfect inversion of the motor unit action potentials (MUAP), noise sources, and the ill-conditioning of the inverse problem. To bridge the gap between theory and practice, we used computer simulations. Main results: (1) Increasing the similarity of MUAPs or correlation between spike trains increases the bias for detecting high amplitude MUs. (2) The optimal objective function depends on the expected spike amplitude, spike amplitude statistics and the amplitude of background spikes. (3) There is some wiggle room for MN detection given non-stationary MUAPs. (4) There is no connection between MUAP duration and extension factor, in contrast to previous guidelines. (5) Source quality metrics like the silhouette score (SIL) or the pulse-to-noise ratio (PNR) are highly correlated with a source's objective function output. (6) SIL is superior to PNR. Significance: These findings will guide cBSS algorithm developments tailored to MN identification and clinical application translation.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。