用于测试空间引力波探测器的可调皮米级稳定干涉仪
Adjustable picometer-stable interferometers for testing space-based gravitational wave detectors
AI总结:
针对空间引力波探测器地面测试需求,提出一种采用可调自由定位支架的超稳定光机干涉仪概念,将组装时间缩短至数小时并实现皮米级长度稳定性,验证了其在低至 3 mHz 频率下噪声低于 1 pm/sqrt(Hz)。
摘要:
空间引力波探测器,例如激光干涉空间天线(LISA),利用皮米精度的激光干涉技术来探测频率从 1 Hz 一直低至 0.1 mHz 以下的引力波。用于此类仪器地面原型构建和测试的激光干涉仪,通常通过永久性粘接或胶合的方式将光学元件固定在由低膨胀微晶玻璃制成的超稳定光学平台上。这种设计最小化了温度对长度和倾斜的耦合效应,由于实验室和真空环境中可实现的温度稳定性有限,该效应在低频段主导了噪声。在此,我们提出了一种替代的光机概念研究,其中光学元件通过可调且可自由定位的支架放置在超稳定平台上,同时保持皮米级的长度稳定性。借助这一概念,由于组装过程得到简化和加速,特定的干涉仪配置能够非常快速地实现,将实现时间从数周或数月缩短至数小时。我们搭建了相应的测试设施,并通过测量在两种不同锁定方案(即外差激光频率稳定和 Pound-Drever-Hall 锁定)下探测的光学腔的长度变化,验证了我们概念的长度稳定性。我们研究了两种锁定方案的局限性,并验证了在低至 3 mHz 的频率下,腔长度噪声低于 1 pm/sqrt(Hz)。我们由此证明,我们的概念能够简化干涉仪配置和光机组件的测试,并且适用于为使用激光干涉技术的太空任务(例如未来的空间引力波探测器和卫星大地测量任务)实现灵活的光学地面支持设备。
英文摘要:
Space-based gravitational wave detectors, such as the Laser Interferometer Space Antenna (LISA), use picometer-precision laser interferometry to detect gravitational waves at frequencies from 1 Hz down to below 0.1 mHz. Laser interferometers used for on-ground prototyping and testing of such instruments are typically constructed by permanently bonding or gluing optics onto an ultra-stable bench made of low-expansion glass ceramic. This design minimizes temperature coupling to length and tilt, which dominates the noise at low frequencies due to finite temperature stability achievable in laboratories and vacuum environments. Here, we present the study of an alternative opto-mechanical concept where optical components are placed with adjustable and freely positionable mounts on an ultra-stable bench, while maintaining picometer length stability. With this concept, a given interferometer configuration can be realised very quickly due to a simplified and speed-up assembly process, reducing the realisation time from weeks or months to a matter of hours. We built a corresponding test facility and verified the length stability of our concept by measuring the length change in an optical cavity that was probed with two different locking schemes, heterodyne laser frequency stabilisation and Pound-Drever-Hall locking. We studied the limitations of both locking schemes and verified that the cavity length noise is below 1 pm/sqrt(Hz) for frequencies down to 3 mHz. We thereby demonstrate that our concept can simplify the testing of interferometer configurations and opto-mechanical components and is suitable to realise flexible optical ground support equipment for space missions that use laser interferometry, such as future space-based gravitational wave detectors and satellite geodesy missions.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。