arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2501.19003cs.CVcs.AI
收藏

用于优化肺活检规划系统中进针点位置的虚拟气道热力图

Virtual airways heatmaps to optimize point of entry location in lung biopsy planning systems

Universitat Autònoma Barcelona(巴塞罗那自治大学);Computer Vision Center(计算机视觉中心);Hospital Universitari de Bellvitge(贝尔维奇大学医院)

Debora Gil, Pere Lloret, Marta Diez-Ferrer, Carles Sanchez

AI总结:

提出基于虚拟气道热力图的肺活检规划模型,通过三维场景模拟评估进针点质量与误差范围,发现病灶形状和距离对活检成功率有显著影响,辅助确定最佳进针点及最大允许误差。

摘要:

目的:我们提出了一个虚拟模型,用于优化肺活检规划系统中的进针点(POE)位置。该模型能够计算从潜在POE获取的活检样本质量,并考虑了规划模拟中的方向与手术实际操作中的方向之间差异所产生的误差范围。此外,本研究还探讨了病灶特征的影响。方法:活检质量通过投影在患者特异性气道模型骨架上的热力图来呈现。该骨架提供了气道结构的三维表示,而热力图强度则代表了从每个POE可能提取的组织量。该组织量由病灶与一个圆锥体的交集决定,该圆锥体代表活检器械插入过程中的不确定区域。圆锥体、病灶和骨架被建模为定义手术干预三维场景的图形对象。结果:我们基于从CT扫描提取的单一解剖结构和两个具有规则与不规则形状的病灶,模拟了干预场景的不同设置。通过系统性地旋转放置在距气道不同距离处的病灶来模拟不同场景。对不同设置下热力图的分析表明,病灶朝向对不规则形状病灶有显著影响,而距离对两种形状的病灶均有影响。结论:所提出的热力图有助于直观评估最佳POE,并识别支气管不同区域是否存在多个最佳POE。它们还允许我们对导航系统中的最大允许误差进行建模,研究哪些变量对手术成功的影响最大,并帮助确定这种影响在何种程度上可能危及手术。

英文摘要:

Purpose: We present a virtual model to optimize point of entry (POE) in lung biopsy planning systems. Our model allows to compute the quality of a biopsy sample taken from potential POE, taking into account the margin of error that arises from discrepancies between the orientation in the planning simulation and the actual orientation during the operation. Additionally, the study examines the impact of the characteristics of the lesion. Methods: The quality of the biopsy is given by a heatmap projected onto the skeleton of a patient-specific model of airways. The skeleton provides a 3D representation of airways structure, while the heatmap intensity represents the potential amount of tissue that it could be extracted from each POE. This amount of tissue is determined by the intersection of the lesion with a cone that represents the uncertainty area in the introduction of biopsy instruments. The cone, lesion, and skeleton are modelled as graphical objects that define a 3D scene of the intervention. Results: We have simulated different settings of the intervention scene from a single anatomy extracted from a CT scan and two lesions with regular and irregular shapes. The different scenarios are simulated by systematic rotation of each lesion placed at different distances from airways. Analysis of the heatmaps for the different settings show a strong impact of lesion orientation for irregular shape and the distance for both shapes. Conclusion: The proposed heatmaps help to visually assess the optimal POE and identify whether multiple optimal POEs exist in different zones of the bronchi. They also allow us to model the maximum allowable error in navigation systems and study which variables have the greatest influence on the success of the operation. Additionally, they help determine at what point this influence could potentially jeopardize the operation.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑