EMD-Fuzzy:一种基于经验模态分解的模糊模型,用于SSVEP的跨刺激迁移学习
EMD-Fuzzy: An Empirical Mode Decomposition Based Fuzzy Model for Cross-Stimulus Transfer Learning of SSVEP
AI总结:
提出EMD-Fuzzy模型,利用EMD提取频率信息并通过FFT在频域实现刺激迁移,结合模糊逻辑解码器,在仅用4个频率的SSVEP跨刺激迁移学习中实现了最先进的离线与在线性能。
摘要:
脑机接口(BCI)实现了直接的大脑与设备通信,稳态视觉诱发电位(SSVEP)范式因其在各个领域中的稳定性和高准确率而备受青睐。在SSVEP BCI系统中,监督学习模型显著优于无监督模型,能在更短时间内实现更高的准确率。然而,长时间的数据采集会导致用户疲劳,甚至引发光敏性癫痫,造成负面的用户体验。因此,缩短校准时间至关重要。为此,跨刺激迁移学习(CSTL)可以通过仅利用部分频率来缩短校准时间。传统的CSTL方法受时域脉冲响应变化的影响,仅适用于相邻频率的迁移,限制了其普遍适用性。我们提出了一种基于经验模态分解(EMD)的模糊模型(EMD-Fuzzy),该模型采用EMD提取关键频率信息,并通过快速傅里叶变换(FFT)在频域实现刺激迁移,以减轻时域差异。结合使用模糊逻辑进行表示学习的Fuzzy Decoder,我们的方法在离线测试中展现了有前景的初步结果,并实现了最先进的性能。在40目标Benchmark数据集上,仅使用4个频率,我们的方法就达到了82.75%(16.30%)的准确率和186.56(52.09)bits/min的信息传输率(ITR)。在在线测试中,我们的方法展现出稳健的有效性,在7名受试者中平均达到了86.30%(6.18%)的准确率。这一表现突显了将EMD和模糊逻辑整合到CSTL的EEG解码中的有效性,并凸显了我们的方法在对一致且可靠的解码至关重要的实时应用中的潜力。
英文摘要:
The Brain-Computer Interface (BCI) enables direct brain-to-device communication, with the Steady-State Visual Evoked Potential (SSVEP) paradigm favored for its stability and high accuracy across various fields. In SSVEP BCI systems, supervised learning models significantly enhance performance over unsupervised models, achieving higher accuracy in less time. However, prolonged data collection can cause user fatigue and even trigger photosensitive epilepsy, creating a negative user experience. Thus, reducing calibration time is crucial. To address this, Cross-Stimulus transfer learning (CSTL) can shorten calibration by utilizing only partial frequencies. Traditional CSTL methods, affected by time-domain impulse response variations, are suitable only for adjacent frequency transfers, limiting their general applicability. We introduce an Empirical Mode Decomposition (EMD) Based Fuzzy Model (EMD-Fuzzy), which employs EMD to extract crucial frequency information and achieves stimulus transfer in the frequency domain through Fast Fourier Transform (FFT) to mitigate time-domain differences. Combined with a Fuzzy Decoder that uses fuzzy logic for representation learning, our approach delivers promising preliminary results in offline tests and state-of-the-art performance. With only 4 frequencies, our method achieved an accuracy of 82.75% (16.30%) and an information transfer rate (ITR) of 186.56 (52.09) bits/min on the 40-target Benchmark dataset. In online tests, our method demonstrates robust efficacy, achieving an averaged accuracy of 86.30% (6.18%) across 7 subjects. This performance underscores the effectiveness of integrating EMD and fuzzy logic into EEG decoding for CSTL and highlights our method's potential in real-time applications where consistent and reliable decoding is crucial.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。