arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2501.17404physics.med-phphysics.ins-det
收藏

Clatterbridge眼部质子治疗束线的带电粒子场LET测量与模拟建模

LET measurements and simulation modelling of the charged particle field for the Clatterbridge ocular proton therapy beamline

School of Physics, University of Melbourne(墨尔本大学物理学院);University of Liverpool(利物浦大学);Cockcroft Institute(科克克罗夫特研究所);Nikhef(荷兰国家核与亚原子物理研究所);Department of Clinical Medicine, Aarhus University(奥胡斯大学临床医学系);Danish Centre for Particle Therapy, Aarhus University Hospital(奥胡斯大学医院丹麦粒子治疗中心);Department of Oncology, University of Oxford(牛津大学肿瘤学系);VSB -- Technical University of Ostrava(俄斯特拉发科技大学);The Clatterbridge Cancer Centre NHS Foundation Trust(克拉特布里奇癌症中心NHS基金会信托);University College London, University of London(伦敦大学学院);Department of Cancer and Genomic Sciences, University of Birmingham(伯明翰大学癌症与基因组科学系)

Jacinta S. L. Yap, Navrit J. S. Bal, Mark D. Brooke, Cristina Oancea, Carlos Granja, Andrzej Kacperek, Simon Jolly, Frank Van den Heuvel, Jason L. Parsons, Carsten P. Welsch

AI总结:

本研究利用MiniPIX-Timepix探测器在Clatterbridge 60 MeV质子束线上测量LET,并通过TOPAS模拟验证,证明探测器可有效解析LET,支持模型适用性。

摘要:

质子治疗通过利用布拉格峰的有利剂量学特性,可以实现高度靶向的治疗。质子穿过材料时,会通过电离及其他相互作用在布拉格峰处沉积其最大能量,从而将最小的多余剂量传递给周围组织和器官。这种能量损失率也通过线性能量转移(LET)来量化,它反映了辐射质量和放射生物学效应。然而,这是一个难以测量的物理量,因为辐射场的表征以及LET对治疗的影响需要先进的工具和技术。MiniPIX-Timepix是一种小型化的混合半导体像素探测器,能够进行高分辨率的光谱跟踪,实现对单个粒子的沉积能量、位置和方向的大范围检测。实验测量在临床设施——Clatterbridge癌症中心进行,该中心配备有一条60 MeV眼部质子治疗束线。在蒙特卡洛代码TOPAS(粒子模拟工具)中开发了一个真实的端到端设施模型,并用于模拟实验条件。探测器以45°和60°的角度垂直于束流放置,并置于不同厚度的聚甲基丙烯酸甲酯(PMMA)块下游,以获取沿剂量沉积深度的数据。利用提供轨迹长度和能量沉积分布的经验簇数据来获得LET谱。在硅中测定的LET值以及布拉格峰上的剂量平均LET与模拟结果总体一致,支持了TOPAS CCC模型的适用性。这项工作探索了MiniPIX探测器测量物理量以解析LET的能力,并讨论了实验考虑因素和进一步的可能性。

英文摘要:

Proton therapy can achieve a highly targeted treatment by utilising the advantageous dosimetric characteristics of the Bragg Peak. Protons traversing through a material will deposit their maximum energy at the Bragg Peak through ionisation and other interactions, transferring minimal excess dose to surrounding tissue and organs. This rate of energy loss is also quantified by the linear energy transfer (LET), which is indicative of radiation quality and radiobiological effects. However it is a challenging physical quantity to measure, as characterisation of radiation fields and the impact of LET on treatment requires advanced tools and technology. The MiniPIX-Timepix is a miniaturised, hybrid semiconductor pixel detector capable of high resolution spectrometric tracking, enabling wide-range detection of the deposited energy, position and direction of single particles. Experimental measurements were performed at a clinical facility, the Clatterbridge Cancer Centre which houses a 60 MeV ocular proton therapy beamline. A realistic end-to-end model of the facility was developed in the Monte Carlo code TOPAS (TOol for PArticle Simulation) and was used to simulate the experimental conditions. The detector was held at 45$^{\circ}$ and 60$^{\circ}$ perpendicular to the beam, and placed downstream of various thickness Polymethyl methacrylate (PMMA) blocks to acquire data along the dose deposition depth. Empirical cluster data providing track length and the energy deposition distributions were used to obtain the LET spectra. The determined values for the LET in silicon and dose averaged LET across the BP show general agreement with simulated results, supporting the applicability of the TOPAS CCC model. This work explores the capability of the MiniPIX detector to measure physical quantities to resolve the LET, and discusses experimental considerations and further possibilities.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑