arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2501.15689physics.med-pheess.SP
收藏

多隔室扩散-弛豫磁共振信号在球面3D-SHORE基中的表示

Multi-compartment diffusion-relaxation MR signal representation in the spherical 3D-SHORE basis

Fabian Bogusz, Tomasz Pieciak

AI总结:

本文提出基于简谐振子基的多隔室扩散-弛豫MR信号表示方法MC-SHORE,通过ℓ1稀疏约束估计微结构度量,在模拟和体内数据上比单隔室非高斯及多隔室单指数方法更准确,并能分离组织内、外及自由水贡献。

摘要:

对多参数序列获得的扩散-弛豫磁共振(MR)信号进行建模,近年来因新技术显著缩短数据采集时间而引起了学界的极大兴趣。研究扩散-弛豫MR数据的一种优选方法是遵循连续介质建模原理,利用核函数来表示组织特征,如弛豫或扩散特性。然而,用预定义信号分量构建合理的字典取决于模型参数空间的采样密度,从而导致模型中每增加一个组织参数,原子数量呈几何级数增长。这使得估计信号中每个原子的贡献变得具有挑战性,尤其是在考虑超越单指数衰减的扩散特征时。本文提出了一种新的基于简谐振子重建与估计的多隔室扩散-弛豫MR信号表示方法(MC-SHORE),该方法兼容散乱采集。所提出的技术通过ℓ1范数对解施加稀疏性约束,并能够估计微结构度量,如返回原点概率和取向分布函数,具体取决于单个体素中所考虑的隔室。该过程已在计算机模拟和体内数据上得到验证,并且能够比单隔室非高斯表示和多隔室单指数衰减技术更准确地逼近扩散-弛豫MR信号,同时保持字典中的原子数量较少。最终,MC-SHORE方法能够从信号中分离出轴突内/轴突外和自由水的贡献,从而减少在组织边界可观察到的部分体积效应。

英文摘要:

Modelling the diffusion-relaxation magnetic resonance (MR) signal obtained from multi-parametric sequences has recently gained immense interest in the community due to new techniques significantly reducing data acquisition time. A preferred approach for examining the diffusion-relaxation MR data is to follow the continuum modelling principle that employs kernels to represent the tissue features, such as the relaxations or diffusion properties. However, constructing reasonable dictionaries with predefined signal components depends on the sampling density of model parameter space, thus leading to a geometrical increase in the number of atoms per extra tissue parameter considered in the model. That makes estimating the contributions from each atom in the signal challenging, especially considering diffusion features beyond the mono-exponential decay. This paper presents a new Multi-Compartment diffusion-relaxation MR signal representation based on the Simple Harmonic Oscillator-based Reconstruction and Estimation (MC-SHORE) representation, compatible with scattered acquisitions. The proposed technique imposes sparsity constraint on the solution via the $\ell_1$ norm and enables the estimation of the microstructural measures, such as the return-to-the-origin probability, and the orientation distribution function, depending on the compartments considered in a single voxel. The procedure has been verified with in silico and in vivo data and enabled the approximation of the diffusion-relaxation MR signal more accurately than single-compartment non-Gaussian representations and multi-compartment mono-exponential decay techniques, maintaining a low number of atoms in the dictionary. Ultimately, the MC-SHORE procedure allows for separating intra-/extra-axonal and free water contributions from the signal, thus reducing the partial volume effect observable in the boundaries of the tissues.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑