arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2412.07433physics.plasm-ph
收藏

皮秒与纳秒E-FISH对氮气中等离子体子弹的侵入性研究

Invasiveness of pico- and nanosecond E-FISH on plasma bullets in nitrogen

A. A. A. Limburg, T. E. W. Keur, R. F. E. Pleijers, S. Nijdam

AI总结:

本文比较了纳秒与皮秒E-FISH对氮气脉冲等离子体射流的侵入性,发现纳秒激光会诱导流注分叉而皮秒激光非侵入,为优化电场诊断提供了依据。

摘要:

电场是驱动所有等离子体的根本力量。电场诱导二次谐波产生(E-FISH)是一种能够以高时间分辨率和空间分辨率获取电场的诊断方法,被认为是非侵入性的,并且可以高灵敏度地应用于几乎所有类型的等离子体。然而,该技术中用作探测的高功率激光束会与气体相互作用并诱导电荷,这些电荷随后可能影响等离子体。本研究将E-FISH应用于向大气空气中流动的N2中的非热脉冲等离子体射流。在这些射流中,电离前沿沿射流轴线传播,具有高度可重复性和周期性,这使得相位分辨测量成为可能。采用一台纳秒脉冲激光器和一台皮秒脉冲激光器作为光源,二者均工作于1064 nm波长。首次对两种激光器测得的E-FISH信号进行了相互比较。两种激光器获得的结果存在显著偏差,这可以用激光诱导的流注导向来解释。通过拍摄等离子体轨迹的ICCD图像观察到这一现象:在等离子体穿过激光束路径的位置,等离子体发生分叉。这表明E-FISH在某些条件下也是侵入性的。使用皮秒激光器获得的剖面与先前在同一等离子体源上基于相干拉曼散射的四波混频结果在定性上具有良好一致性,因此皮秒激光器被认为是非侵入性的。在未来的E-FISH测量中,应考虑激光束对E-FISH信号的影响,以防止改变等离子体行为。通过降低激光功率或使用更短的激光脉冲,可以成功进行测量。

英文摘要:

The electric field is the driving force behind every plasma. Electric field induced second harmonic generation (E-FISH) is a diagnostic able to obtain the electric field with high temporal and spatial resolution, is considered non-invasive and can be applied to almost any type of plasma with high sensitivity. However, the high power laser beam used as a probe in this technique, can interact with the gas and induce charges, which can subsequently influence the plasma. In this work, E-FISH is applied on non-thermal pulsed plasma jets in N2 flowing into atmospheric air. In these jets, ionization fronts propagate along the axis of the jet, which are highly reproducible and periodic. This allows for phase resolved measurements. A nanosecond and a picosecond pulsed laser, both operating at 1064 nm, are used as sources. For the first time, the obtained E-FISH signals measured with both lasers are compared to each other. The results deviate significantly between the two lasers, which can be explained by laser induced guiding of the streamers. This is observed by taking ICCD images of the plasma trajectory. At the position where the plasma crosses the laser beam path, the plasma branches. This reveals that E-FISH is also invasive under some conditions. The profiles obtained with the picosecond laser are in good qualitative agreement with previous coherent Raman scattering-based four-wave mixing results on the same plasma source and therefore the picosecond laser is considered non-invasive. In future E-FISH measurements, the influence of the laser beam on the E-FISH signal should be taken into account to prevent changing the plasma behavior. By decreasing the laser power or using a shorter laser pulse, successful measurements can be performed.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑