DETR and its variants have emerged as promising architectures for object detection, offering an end-to-end prediction pipeline. In practice, however, DETRs generate hundreds of predictions that far outnumber the actual objects present in an image. This raises a critical question: which of these predictions could be trusted? This is particularly important for safety-critical applications, such as in autonomous vehicles. Addressing this concern, we provide empirical and theoretical evidence that predictions within the same image play distinct roles, resulting in varying reliability levels. Our analysis reveals that DETRs employ an optimal specialist strategy: one prediction per object is trained to be well-calibrated, while the remaining predictions are trained to suppress their foreground confidence to near zero, even when maintaining accurate localization. We show that this strategy emerges as the loss-minimizing solution to the Hungarian matching, fundamentally shaping DETRs' outputs. While selecting the well-calibrated predictions is ideal, they are unidentifiable at inference time. This means that any post-processing algorithm poses a risk of outputting a set of predictions with mixed calibration levels. Therefore, practical deployment necessitates a joint evaluation of both the model's calibration quality and the effectiveness of the post-processing algorithm. However, we demonstrate that existing metrics like average precision and expected calibration error are inadequate for this task. To address this issue, we further introduce Object-level Calibration Error (OCE): This object-centric design penalizes both retaining suppressed predictions and missed ground truth foreground objects, making OCE suitable for both evaluating models and identifying reliable prediction subsets. Finally, we present a post hoc uncertainty quantification framework that predicts per-image model accuracy.
Fiber-Resolved Microstructure Quantification from Multi-Shell Diffusion MRI using Detection Transformers
AImotion Bavaria, Technische Hochschule Ingolstadt(AImotion Bavaria,英戈尔施塔特应用技术大学);TUM School of Computation, Information and Technology, Technical University of Munich(慕尼黑工业大学计算、信息与技术学院);TUM School of Natural Sciences, Technical University of Munich(慕尼黑工业大学自然科学学院)
calibfusion: Transformer-Based Differentiable Calibration for Radar-Camera Fusion Detection in Water-Surface Environments
School of Artificial Intelligence, University of Chinese Academy of Sciences(中国科学院大学人工智能学院);Institute of Automation, Chinese Academy of Sciences(中国科学院自动化研究所)
Uncertainty-Aware Online Extrinsic Calibration: A Conformal Prediction Approach
Université de technologie de Compiègne, CNRS, Heudiasyc(法国图卢兹工学院、CNRS、Heudiasyc);CNRS, INSA Lyon, UCBL, LIRIS, UMR5205(CNRS、里昂国立应用科学学院、UCBL、LIRIS、UMR5205)
Balancing Accuracy, Calibration, and Efficiency in Active Learning with Vision Transformers Under Label Noise
Department of Information and Computer Sciences, University of Hawai‘i at Manoa(夏威夷大学马诺亚分校信息与计算机科学系);Department of Computer Science, University of Pretoria(pretoria大学计算机科学系)
Vision Transformer using Low-level Chest X-ray Feature Corpus for COVID-19 Diagnosis and Severity Quantification
Korea Advanced Institute of Science and Technology (KAIST)(韩国科学技术院);Asan Medical Center, University of Ulsan College of Medicine(蔚山大学医学院峨山医学中心);College of Medicine, Yeungnam University(岭南大学医学院);School of Medicine, Kyungpook National University(庆北国立大学医学院)
Probing Routing-Conditional Calibration in Attention-Residual Transformers
Adelaide University(阿德莱德大学);Australian Institute for Machine Learning (AIML), Adelaide University(澳大利亚机器学习研究所(AIML),阿德莱德大学);The University of Queensland(昆士兰大学)
Muscle volume quantification: guiding transformers with anatomical priors
Nantes Université(南特大学);École Centrale Nantes(南特中央理工学院);Technical University of Munich (TUM)(慕尼黑工业大学);INSEP(法国国家体育学院);Fédération Française de Badminton(法国羽毛球联合会)
Severity Quantification and Lesion Localization of COVID-19 on CXR using Vision Transformer
Korea Advanced Institute of Science and Technology(韩国科学技术院);Asan Medical Center(峨山医院);University of Ulsan College of Medicine(蔚山大学医学院);College of Medicine, Chungnam National Univerity(忠南国立大学医学院);College of Medicine, Yeungnam University(岭南大学医学院);School of Medicine, Kyungpook National University(庆北国立大学医学院)
CalibNet: Geometrically Supervised Extrinsic Calibration using 3D Spatial Transformer Networks
International Institute of Information Technology, Hyderabad(海得拉巴国际信息技术学院);Mila(米拉研究所);Université de Montréal(蒙特利尔大学)
3D LiDAR和2D相机越来越多地在传感器设备中同时使用,以执行感知任务。然而,在这些传感器可以用于收集有意义的数据之前,它们的外部(和内部)需要被精确校准,因为传感器装置的性能对这些校准参数非常敏感。绝大多数现有的校准技术需要大量的数据和/或校准目标和人力,严重影响了它们在大规模生产系统中的适用性。我们通过CalibNet解决了这一差距:一个自监督的深度网络,能够实时自动估计3D LiDAR和2D相机之间的6自由度刚体变换。CalibNet减少了对校准目标的需求,从而大大节省了校准工作。在训练过程中,网络仅将LiDAR点云、相应的单目图像和相机校准矩阵K作为输入。在训练时,我们不进行直接监督(即,例如,我们不直接回归到校准参数)。相反,我们训练网络来预测校准参数,以最大限度地提高输入图像和点云的几何和光度一致性。CalibNet学习迭代解决潜在的几何问题,并准确预测各种错误校准的外部校准参数,而无需重新训练或领域自适应。该项目的页面位于https://epiception.github.io/CalibNet
Brain Tumor Classification using Vision Transformer with Selective Cross-Attention Mechanism and Feature Calibration
K.N. Toosi University of Technology(霍梅尼国际大学(K.N. Toosi理工大学));Indiana University-Purdue University(印第安纳大学-普渡大学);Shahed university(沙希德大学);University of Cincinnati(辛辛那提大学)
Vision Transformer-based Model for Severity Quantification of Lung Pneumonia Using Chest X-ray Images
University of the Basque Country(巴斯克大学);IKERBASQUE;Ho Chi Minh City Open University(胡志明市开放大学);University of Strasbourg(斯特拉斯堡大学);INSERM(法国国家健康与医学研究院);Université de Haute-Alsace(上阿尔萨斯大学)
本文提出 ViTReg-IP,一种由 ViT 与回归头构成的轻量模型,用于根据胸部 X 光量化 COVID-19 等肺病严重程度,并在多来源数据集上验证其低成本、高性能与泛化性。
Self-Supervised Learning for Organs At Risk and Tumor Segmentation with Uncertainty Quantification
University of Central Florida(中佛罗里达大学);Northwestern University(西北大学);KnowledgeVis LLC(KnowledgeVis有限责任公司);Orlando Health(奥兰多健康);University of Chicago(芝加哥大学)
Uncertainty quantification in non-rigid image registration via stochastic gradient Markov chain Monte Carlo
Imperial College London(帝国理工学院);Technische Universität München(慕尼黑工业大学);Sharif University of Technology(谢里夫理工大学);Friedrich-Alexander-Universität Erlangen-Nürnberg(埃尔朗根-纽伦堡大学)