arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2411.09201cs.AReess.SP
收藏

使用毫米波 MIMO 雷达进行非接触式多点生命体征监测

Noncontact Multi-Point Vital Sign Monitoring with mmWave MIMO Radar

Wei Ren, Jiannong Cao, Huansheng Yi, Kaiyue Hou, Miaoyang Hu, Jianqi Wang, Fugui Qi

AI总结:

针对传统方法无法精确监测多点生命体征的局限,本文提出 MultiVital 系统,利用毫米波 MIMO 雷达结合多模态信号处理框架,实现了高精度非接触式多点胸壁振动同步监测。

摘要:

多点生命体征监测对于提供生理变化的详细洞察至关重要。传统的单传感器方法无法捕捉多点振动。现有的接触式解决方案虽然满足了这一需求,但会引起不适和皮肤过敏,而非接触式光学和声学方法极易受光线干扰和环境噪声的影响。在本文中,我们旨在开发一种使用 MIMO 雷达的非接触式多点生命体征监测技术,重点是在物理上区分并精确测量由心肺机械活动引起的胸壁表面多点振动。开发此类技术的主要挑战涉及开发提取和分离纠缠信号的算法,以及建立验证检测准确性的可靠方法。为了解决这些限制,我们引入了 MultiVital,这是一种利用毫米波多输入多输出(MIMO)雷达进行同步多点生命体征监测的无线系统。它集成了两种参考模态:五通道心震图(SCG)传感器和单通道心电图(ECG)电极,从而能够基于雷达对多种生理指标进行全面的研究和性能验证。此外,我们开发了一个多模态信号处理框架,由雷达信号处理模块、SCG 校准模块和空间对齐方案组成。为了评估雷达信号处理模块,我们进行了数学推导和仿真。实验结果表明,非接触式 MultiVital 系统实现了高精度的多点同步监测,与参考模态的结果高度一致。

英文摘要:

Multi-point vital sign monitoring is essential for providing detailed insights into physiological changes. Traditional single-sensor approaches are inadequate for capturing multi-point vibrations. Existing contact-based solutions, while addressing this need, can cause discomfort and skin allergies, whereas noncontact optical and acoustic methods are highly susceptible to light interference and environmental noise. In this paper, we aim to develop a non-contact, multi-point vital sign monitoring technique using MIMO radar, focused on physically differentiating and precisely measuring chest-wall surface vibrations at multiple points induced by cardiopulmonary mechanical activity. The primary challenges in developing such a technique involve developing algorithms to extract and separate entangled signals, as well as establishing a reliable method for validating detection accuracy. To address these limitations, we introduce MultiVital, a wireless system that leverages mmWave Multiple-input Multiple-output (MIMO) radar for synchronous multi-point vital sign monitoring. It integrates two reference modalities: five-channel seismocardiography (SCG) sensors and a one-channel electrocardiogram (ECG) electrode, enabling comprehensive radar-based research and performance validation across multiple physiological metrics. Additionally, we have developed a multi-modal signal processing framework, consisting of a radar signal processing module, an SCG calibration module, and a spatial alignment scheme. To evaluate the radar signal processing module, we conducted mathematical derivation and simulation. The experimental results indicate that the noncontact MultiVital system achieves multi-point synchronous monitoring with high precision, highly consistent with the results from reference modalities.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑