零间距碱性水电解池中气体分布的X射线测量

X-ray measurements of gas distribution in a zero gap alkaline water electrolyzer

On-Yu Dung, Stephan Boden, Albertus W. Vreman, Niels G. Deen, Markus Schubert, Yali Tang

AI总结:

利用X射线透视技术测量零/窄间距碱性水电解池的动态空隙率,发现间隙区空隙率高于主体,零间距电势最低,且穿孔箔电极能抑制液体串流和氧空隙率超标现象。

摘要:

使用X射线透视技术测量了零/窄间距碱性水电解池中的二维投影动态空隙率,空间分辨率为15 $μ$m,窄间距尺寸最高至300 $μ$m,电流密度最高至0.54 A/cm$^2$。正如预期,主体内的空隙率沿电池高度方向增加,并随电流密度增加而增大。在间隙区域(隔膜与电极及其孔洞之间的空间)测得的空隙率始终大于主体中的空隙率。在低于0.3 A/cm$^2$的电流密度下,它几乎不依赖于间隙尺寸。零间距时测得了最低的电池电势。未发现间隙中存在隔离气袋/气膜的证据。对于多孔板电极,发生了液体串流和氧空隙率超过氢空隙率的现象,但对于穿孔箔电极,这些现象被抑制了。

英文摘要:

X-ray radioscopy was used to measure the 2D projected dynamic void fraction in a zero/narrow gap alkaline water electrolyzer at a spatial resolution of 15 $μ$m, for narrow gap sizes up to 300 $μ$m and current densities up to 0.54 A/cm$^2$. As expected, the void fraction in the bulk was found to increase along the cell height and with increasing current density. The void fraction measured in the gap region (the space between the diaphragm and the electrode and its holes) was always larger than in the bulk. It hardly depended on the gap size at current densities below 0.3 A/cm$^2$. The lowest cell potential was measured for zero gap. No evidence of isolating gas pockets/films in the gaps was found. Liquid crossover and oxygen void fraction exceeding the hydrogen void fraction occurred for porous plate electrodes, but these phenomena were suppressed for perforated foil electrodes.