利用Loreli II 21厘米信号辐射流体模拟数据库比较贝叶斯推断方法
Comparison of Bayesian inference methods using the Loreli II database of hydro-radiative simulations of the 21-cm signal
AI总结:
本文利用近万组21厘米信号模拟数据库Loreli II,比较功率谱仿真器、神经密度估计器和贝叶斯神经网络三种推断方法,发现显式高斯似然在当前噪声水平下已足够,并将其应用于HERA数据得到对X射线发射率的弱约束。
摘要:
尽管观测来自宇宙黎明和再电离时期的21厘米信号在仪器上是一项挑战,但对潜在探测结果的解释仍面临一些未解问题,涉及信号建模以及连接理论与观测的贝叶斯推断技术。为解决其中部分问题,我们提出了Loreli II,这是一个使用Licorice三维辐射转移代码运行的近10 000个21厘米信号模拟数据库。借助Loreli II,我们探索了一个5维天体物理参数空间,其中恒星形成、X射线发射和紫外发射均被改变。随后,我们利用该数据库训练神经网络,并对受热噪声影响的21厘米功率谱进行贝叶斯推断,噪声水平对应平方公里阵列100小时观测。我们研究并比较了三种推断技术:功率谱仿真器、拟合模型隐式似然的神经密度估计器,以及直接拟合后验分布的贝叶斯神经网络。我们通过在统计上具有代表性的推断集合上对每种方法进行比较来衡量其性能,尤其使用了基于模拟的校准原则。我们报告的一维边缘化后验误差(偏差和过度/不足置信)对仿真器低于标准差的15%,对其他方法低于25%。我们得出结论:在我们的噪声水平和参数空间采样密度下,显式高斯似然是足够的。在更低噪声水平或使用更密集采样以达到更高精度时,情况可能并非如此。随后,我们将仿真器方法应用于最近的HERA上限,并报告了对我们模型中X射线发射率参数的较弱约束。
英文摘要:
While the observation of the 21 cm signal from the Cosmic Dawn and Epoch of Reionization is an instrumental challenge, the interpretation of a prospective detection is still open to questions regarding the modelling of the signal and the Bayesian inference techniques that bridge the gap between theory and observations. To address some of these questions, we present Loreli II, a database of nearly 10 000 simulations of the 21 cm signal run with the Licorice 3D radiative transfer code. With Loreli II, we explore a 5-dimensional astrophysical parameter space where star formation, X-ray emissions, and UV emissions are varied. We then use this database to train neural networks and perform Bayesian inference on 21 cm power spectra affected by thermal noise at the level of 100 hours of observation with the Square Kilometer Array. We study and compare three inference techniques : an emulator of the power spectrum, a Neural Density Estimator that fits the implicit likelihood of the model, and a Bayesian Neural Network that directly fits the posterior distribution. We measure the performances of each method by comparing them on a statistically representative set of inferences, notably using the principles of Simulation-Based Calibration. We report errors on the 1-D marginalized posteriors (biases and over/under confidence) below $15 \%$ of the standard deviation for the emulator and below $25 \%$ for the other methods. We conclude that at our noise level and our sampling density of the parameter space, an explicit Gaussian likelihood is sufficient. This may not be the case at lower noise level or if a denser sampling is used to reach higher accuracy. We then apply the emulator method to recent HERA upper limits and report weak constraints on the X-ray emissivity parameter of our model.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。