arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2410.09197cond-mat.supr-concond-mat.mtrl-sci
收藏

利用Bean模型计算临界电流密度的具有自洽磁学单位的表达式

Expression with self-consistent magnetic units for calculation of critical current density using the Bean's Model

M. Polichetti, A. Galluzzi, R. Kumar, A. Goyal

AI总结:

针对Bean模型估算临界电流密度Jc,mag时因磁学单位和前置因子混用导致的误差问题,提出带无量纲前置因子的通用方程,解决了计算歧义,避免误差传播。

摘要:

本研究借助Bean临界态模型,利用Gyorgy等人提出的方程以及文献中报道的由其推导的其他类似方程,分析了临界电流密度Jc,mag的计算。尽管使用Bean模型估算Jc,mag的做法已十分普遍,但对带有不同磁学单位和前置因子的不同方程的不当使用,造成了混淆,还导致已报道的Jc,mag数值存在显著误差。本研究提出了一个单一通用方程,用于借助Bean临界态模型计算垂直场中长方体样品的Jc,mag,阐明了只需简单转换磁学单位,即可得到所需单位下的Jc,mag,无需引入任何其他修正,也不用根据Jc,mag的单位使用其他特定方程。该方程中的数值前置因子是无量纲的,与所使用的单位制无关。研究对比了文献中报道的表达式,结果表明这些表达式会因所用单位不同而得出不同结果,且这些结果与本研究提出的通用方程得到的正确结果相比,差异至少可达一个数量级。该研究解决了所有歧义,符合正确的量纲分析,消除了Jc,mag计算中的不一致性,还将避免文献中误差的进一步传播。

英文摘要:

This study analyzes the calculation of the critical current density Jc,mag by means of Bean's critical state model, using the equation formulated by Gyorgy et al. and other similar equations derived from it reported in the literature. While estimations of Jc,mag using Bean's model are widely performed, improper use of different equations with different magnetic units and pre-factors leads to confusion and to significant errors in the reported values of Jc,mag. In this work, a SINGLE general equation is proposed for the calculation of Jc,mag for a rectangular parallelepiped sample in perpendicular field using Bean's critical state model, underlying how the simple conversion of magnetic units can lead to a Jc,mag in the desired units, without the need to introduce any other correction or use other specific equations depending on the units of Jc,mag. In this equation, the numerical pre-factor is dimensionless, independent of the unit system used. A comparison between the expression reported in the literature is done, showing how they can lead to different results depending on the used units, and that these results can be at least one order of magnitude different from the correct results obtained with the general equation proposed in this work. This resolves all ambiguities and aligns with the correct dimensional analysis, eliminates discrepancies in the calculated Jc,mag, and will avoid further propagation of errors in the literature.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑