arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2410.08799cs.NIeess.SP
收藏

干扰耦合与被动冷却基站的智能热管理在线学习

Online Learning for Intelligent Thermal Management of Interference-coupled and Passively Cooled Base Stations

Zhanwei Yu, Yi Zhao, Xiaoli Chu, Di Yuan

AI总结:

针对被动冷却基站(PCBSs)在室外散热不确定及多小区干扰耦合下的热管理难题,提出基于软执行器-评论器(SAC)的强化学习在线决策方法,结合拒绝与奖励机制防止过热,在无未来散热先验知识下实现总下行吞吐量最大化,达到全局最优的88.6%。

摘要:

被动冷却基站(PCBSs)的出现提供了更好的成本和能源效率。然而,被动冷却需要通过流量管理进行智能热控制,即PCBS的瞬时数据流量或吞吐量直接影响其热性能。这对于PCBS的室外部署尤其具有挑战性,因为散热效率不确定且随时间波动。此外,在多小区场景中,PCBSs是干扰耦合的。因此,吞吐量较高的PCBS会对其他PCBS造成较高的干扰,这反过来需要更多的资源消耗来满足各自的吞吐量目标。在本文中,我们解决了在受运行温度相关约束的条件下,最大化多PCBS系统总下行吞吐量的在线决策问题。我们证明了一种强化学习(RL)方法,特别是软执行器-评论器(SAC),能够通过使吞吐量适应时变的散热条件,在保持PCBS冷却的同时成功实现吞吐量最大化。此外,我们设计了一种拒绝和奖励机制,有效降低了RL探索阶段过热的风险。仿真结果表明,我们的方法达到了全局最优的88.6%。这非常有前景,因为我们的方法在不需要全局最优所需的未来散热效率先验知识的情况下运行。

英文摘要:

Passively cooled base stations (PCBSs) have emerged to deliver better cost and energy efficiency. However, passive cooling necessitates intelligent thermal control via traffic management, i.e., the instantaneous data traffic or throughput of a PCBS directly impacts its thermal performance. This is particularly challenging for outdoor deployment of PCBSs because the heat dissipation efficiency is uncertain and fluctuates over time. What is more, the PCBSs are interference-coupled in multi-cell scenarios. Thus, a higher-throughput PCBS leads to higher interference to the other PCBSs, which, in turn, would require more resource consumption to meet their respective throughput targets. In this paper, we address online decision-making for maximizing the total downlink throughput for a multi-PCBS system subject to constraints related on operating temperature. We demonstrate that a reinforcement learning (RL) approach, specifically soft actor-critic (SAC), can successfully perform throughput maximization while keeping the PCBSs cool, by adapting the throughput to time-varying heat dissipation conditions. Furthermore, we design a denial and reward mechanism that effectively mitigates the risk of overheating during the exploration phase of RL. Simulation results show that our approach achieves up to 88.6% of the global optimum. This is very promising, as our approach operates without prior knowledge of future heat dissipation efficiency, which is required by the global optimum.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑