arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2410.00029cs.HCeess.SP

电极位置对前臂方向不变手势识别的影响

Impact of Electrode Position on Forearm Orientation Invariant Hand Gesture Recognition

Md. Johirul Islam, Umme Rumman, Arifa Ferdousi, Md. Sarwar Pervez, Iffat Ara, Shamim Ahmad, Fahmida Haque, Sawal Hamid, Md. Ali, Kh Shahriya Zaman, Mamun Bin Ib… 展开作者

Md. Johirul Islam, Umme Rumman, Arifa Ferdousi, Md. Sarwar Pervez, Iffat Ara, Shamim Ahmad, Fahmida Haque, Sawal Hamid, Md. Ali, Kh Shahriya Zaman, Mamun Bin Ibne Reaz, Mustafa Habib Chowdhury, Md. Rezaul Islam

AI总结:

本研究通过19名受试者和12种手势实验,证明前臂电极位置相比肘部位置能提升最高5.35%的前臂方向不变手势识别性能,并验证了其鲁棒性,为肌电假肢和人机交互设备优化电极布局提供了依据。

摘要:

目的:前臂方向变化是严重影响前臂方向不变手势识别性能或自由度的关键因素之一,并限制了肌电假肢手或基于肌电图(EMG)信号的人机交互设备的成功商业化。本研究探讨了表面EMG电极位置(肘部和前臂)对前臂方向不变手势识别的影响。方法:本研究在19名肢体完好的受试者上进行,考虑了12种日常生活手势。通过三个指标确认了EMG信号的质量。然后,通过考虑三种训练策略、六种特征提取方法和三种分类器,对识别性能进行评估和验证。结果:就三个指标而言,前臂电极位置提供了与肘部电极位置相当或更好的EMG信号质量。在本研究中,与肘部电极位置相比,前臂电极位置实现了最高5.35%的前臂方向不变手势识别性能提升。所获得的性能通过考虑六种特征提取方法、三种分类器和实时实验进行了验证。此外,结合近期工作,前臂电极位置在识别性能、所研究手势、通道数量、特征空间维数和受试者数量方面表现出鲁棒性。结论:前臂电极位置可能是获得改进的前臂方向不变手势识别性能的最佳选择。意义:通过这种优化的电极位置,可以提高肌电假肢和人机交互设备的性能。

英文摘要:

Objective: Variation of forearm orientation is one of the crucial factors that drastically degrades the forearm orientation invariant hand gesture recognition performance or the degree of freedom and limits the successful commercialization of myoelectric prosthetic hand or electromyogram (EMG) signal-based human-computer interfacing devices. This study investigates the impact of surface EMG electrode positions (elbow and forearm) on forearm orientation invariant hand gesture recognition. Methods: The study has been performed over 19 intact limbed subjects, considering 12 daily living hand gestures. The quality of the EMG signal is confirmed in terms of three indices. Then, the recognition performance is evaluated and validated by considering three training strategies, six feature extraction methods, and three classifiers. Results: The forearm electrode position provides comparable to or better EMG signal quality considering three indices. In this research, the forearm electrode position achieves up to 5.35% improved forearm orientation invariant hand gesture recognition performance compared to the elbow electrode position. The obtained performance is validated by considering six feature extraction methods, three classifiers, and real-time experiments. In addition, the forearm electrode position shows its robustness with the existence of recent works, considering recognition performance, investigated gestures, the number of channels, the dimensionality of feature space, and the number of subjects. Conclusion: The forearm electrode position can be the best choice for getting improved forearm orientation invariant hand gesture recognition performance. Significance: The performance of myoelectric prosthesis and human-computer interfacing devices can be improved with this optimized electrode position.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑