arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2409.18226physics.flu-dynphysics.app-ph
收藏

薄壁选择性激光熔化中激光冲击区的二维传热与熔体流动——II:建模

Two-dimensional heat transfer and melt flow in the laser-impact zone at selective laser melting of thin walls -- II: Modeling

Andrey V. Gusarov, Tatiana V. Tarasova, Sergey N. Grigoriev

AI总结:

本文为薄壁选择性激光熔化建立二维传热与熔体流动CFD模型,揭示熔池涡流特征及混合不足现象,并提出误差在10%以内的熔池深度解析模型,发现熔深与线能量密度成正比,有助于优化SLM工艺。

摘要:

本文第二部分涉及对第一部分所得实验数据进行建模与分析。开发了一个二维导热传热与热毛细驱动对流的计算流体力学(CFD)模型。质量、动量和能量守恒定律通过二阶Godunov有限体积法进行数值求解,使用了为所应用的状态方程开发的原创Riemann求解器。通过与实验对比验证了该CFD模型。揭示了熔池中两个向外涡流的形成。表面活性杂质可使表面张力-温度函数变为非单调的,从而产生具有相反向内流动方向的附加涡流。在选择性激光熔化(SLM)条件下,熔体对流对熔池尺寸的影响不大。熔池中的流速约为或低于激光扫描速度。这意味着熔池内混合不充分。在SLM中使用粉末混合物时,不能期望化学成分完全均质化。仔细研究了Rosenthal模型误差与熔化潜热之间的相关性,得出了一个用于估算熔池深度的解析模型。在所研究的SLM案例中,所开发解析模型的精度相对于CFD模型在10%以内。所得实验和理论结果表明,在SLM的典型条件下,熔化深度近似与线能量密度LED成正比。这在优化SLM工艺时可能有用。

英文摘要:

Part II of the present work concerns modeling and analyzing the experimental data obtained in Part I. A computational fluid dynamics (CFD) model of two-dimensional conductive heat transfer and thermocapillary-driven convection is developed. The conservation laws for mass, momentum, and energy are numerically solved by a second-order Godunov finite-volume method using an original Riemann solver developed for the applied equation of state. The CFD model is validated by comparison with the experiments. Formation of two outward vortices in the melt pool is revealed. Surface-active impurities can make the surface tension-temperature function non-monotonous giving raise additional vortices with the opposite inward flow direction. The influence of melt convection on the melt pool size is not considerable in the conditions of selective laser melting (SLM). The flow velocity in the melt pool is around or less than the laser scanning speed. This means insufficient mixing in the melt pool. One cannot expect a complete homogenization of chemical composition when using powder blends in SLM. The correlation between the error of the Rosenthal model and the latent heat of fusion is carefully studied resulting an analytical model for estimating the melt pool depth. In the studied SLM cases, the accuracy of the developed analytical model is within 10% relative the CFD model. The obtained experimental and theoretical results indicate that the melt depth is approximately proportional to linear energy density LED in the typical conditions of SLM. This can be useful when optimizing the SLM process.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑