arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2409.17340cs.ROcs.AImath.DS
收藏

通过肌电传感实现Koopman驱动的抓握力预测

Koopman-driven grip force prediction through EMG sensing

University of Rijeka(里耶卡大学);University of California, Santa Barbara(加州大学圣巴巴拉分校);AIMdyn, Inc.(AIMdyn公司)

Tomislav Bazina, Ervin Kamenar, Maria Fonoberova, Igor Mezić

AI总结:

本文通过单个肌电传感器对中等缠绕抓握中的抓握力进行准确预测,利用Koopman算子理论和数据提升技术,实现快速且鲁棒的力估计与短期预测,wMAPE为5.5%。

摘要:

由于中风或多发性硬化等疾病导致的手部功能丧失严重影响日常生活活动。机器人康复提供了恢复手部功能的工具,而基于表层肌电图(sEMG)的新方法使设备的力输出能够根据用户状况进行调整,从而提高康复效果。本研究旨在利用单个sEMG传感器对中等缠绕抓握过程中的抓握力进行准确估计,解决精确预测中传感器需求增加的挑战。我们对13名受试者在两个前臂位置进行了sEMG测量,并通过手部测力计验证结果。我们建立了灵活的信号处理步骤,使处理后的sEMG信号(代表有意义的肌肉活动)与抓握力之间的峰值互相关系数较高。通过敏感性分析确定了影响参数。利用一种基于Koopman算子理论的新数据驱动方法和问题特定的数据提升技术,我们设计了一种从处理后的sEMG信号中估计和短期预测抓握力的方法。估计的抓握力的加权平均绝对百分比误差(wMAPE)约为5.5%,而具有0.5秒预测范围的预测结果wMAPE约为17.9%。该方法在精确电极定位方面表现出鲁棒性,因为传感位置对误差指标的影响不显著。该算法执行速度极快,处理、估计和预测0.5秒的sEMG信号批次仅需约30毫秒,从而实现实时应用。

英文摘要:

Loss of hand function due to conditions like stroke or multiple sclerosis significantly impacts daily activities. Robotic rehabilitation provides tools to restore hand function, while novel methods based on surface electromyography (sEMG) enable the adaptation of the device's force output according to the user's condition, thereby improving rehabilitation outcomes. This study aims to achieve accurate force estimations during medium wrap grasps using a single sEMG sensor pair, thereby addressing the challenge of escalating sensor requirements for precise predictions. We conducted sEMG measurements on 13 subjects at two forearm positions, validating results with a hand dynamometer. We established flexible signal-processing steps, yielding high peak cross-correlations between the processed sEMG signal (representing meaningful muscle activity) and grip force. Influential parameters were subsequently identified through sensitivity analysis. Leveraging a novel data-driven Koopman operator theory-based approach and problem-specific data lifting techniques, we devised a methodology for the estimation and short-term prediction of grip force from processed sEMG signals. A weighted mean absolute percentage error (wMAPE) of approx. 5.5% was achieved for the estimated grip force, whereas predictions with a 0.5-second prediction horizon resulted in a wMAPE of approx. 17.9%. The methodology proved robust regarding precise electrode positioning, as the effect of sensing position on error metrics was non-significant. The algorithm executes exceptionally fast, processing, estimating, and predicting a 0.5-second sEMG signal batch in just approx. 30 ms, facilitating real-time implementation.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑