arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2409.17024eess.SP
收藏

利用便携式L波段微波辐射计进行亚米级土壤湿度遥感

Sub-Meter Remote Sensing of Soil Moisture Using Portable L-band Microwave Radiometer

University of Illinois Urbana-Champaign(伊利诺伊大学厄巴纳-香槟分校)

Runze Zhang, Abhi Nayak, Derek Houtz, Adam Watts, Elahe Soltanaghai, Mohamad Alipour

AI总结:

本研究利用便携式L波段微波辐射计评估亚米级土壤湿度的准确性,验证了SMAP算法在PoLRa数据处理中的有效性。

摘要:

尽管遥感卫星的微波被动土壤湿度产品以准确性著称,但通常受限于粗略的空间分辨率。这限制了其捕捉更细的土壤湿度梯度的能力,阻碍了其应用。便携式L波段辐射计(PoLRa)能够根据测量高度的不同,提供从亚米到几十米的土壤湿度测量。鉴于该传感器的土壤湿度评估存在明显不足,本研究旨在评估PoLRa安装在杆上在美国内布拉斯加州中部四个不同地点的亚米级土壤湿度的性能。评估重点在于PoLRa在不同方向上测量的亮度温度相对于同一区域的一致性,以及PoLRa推导出的土壤湿度的准确性。由于PoLRa在许多方面与NASA土壤湿度主动被动(SMAP)任务上的L波段辐射计相似,因此应用了两种SMAP操作算法和传统双通道算法来计算从测量亮度温度得到的土壤湿度。PoLRa的垂直极化亮度温度通常比水平极化对应的更稳定。在每个测试期间,观察到的双极化亮度温度的标准差通常小于5K。通过将PoLRa基于的土壤湿度推导结果与手持式时域反射计获得的湿度值进行比较,无偏根均方误差和皮尔逊相关系数大多低于0.04且高于0.75,证实了PoLRa推导出的土壤湿度推导的高精度以及利用SMAP算法处理PoLRa数据的可行性。这些发现突显了地面或无人机基于的PoLRa测量作为未来遥感L波段传感器独立参考的重要潜力。

英文摘要:

Spaceborne microwave passive soil moisture products are known for their accuracy but are often limited by coarse spatial resolutions. This limits their ability to capture finer soil moisture gradients and hinders their applications. The Portable L band radiometer (PoLRa) offers soil moisture measurements from submeter to tens of meters depending on the altitude of measurement. Given that the assessments of soil moisture derived from this sensor are notably lacking, this study aims to evaluate the performance of submeter soil moisture retrieved from PoLRa mounted on poles at four different locations in central Illinois, USA. The evaluation focuses on the consistency of PoLRa measured brightness temperatures from different directions relative to the same area, and the accuracy of PoLRa derived soil moisture. As PoLRa shares many aspects of the L band radiometer onboard the NASA Soil Moisture Active Passive (SMAP) mission, two SMAP operational algorithms and the conventional dual channel algorithm were applied to calculate soil moisture from the measured brightness temperatures. The vertically polarized brightness temperatures from the PoLRa are typically more stable than their horizontally polarized counterparts. In each test period, the standard deviations of observed dual polarization brightness temperatures are generally less than 5 K. By comparing PoLRa based soil moisture retrievals against the moisture values obtained by handheld time domain reflectometry, the unbiased root mean square error and the Pearson correlation coefficient are mostly below 0.04 and above 0.75, confirming the high accuracy of PoLRa derived soil moisture retrievals and the feasibility of utilizing SMAP algorithms for PoLRa data. These findings highlight the significant potential of ground or drone based PoLRa measurements as a standalone reference for future spaceborne L band sensors.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑