MP2RAGE定量T1值与多TI反转恢复T1值的比较与校准

Comparison and calibration of MP2RAGE quantitative T1 values to multi-TI inversion recovery T1 values

Adam M. Saunders, Michael E. Kim, Chenyu Gao, Lucas W. Remedios, Aravind R. Krishnan, Kurt G. Schilling, Kristin P. O'Grady, Seth A. Smith, Bennett A. Landman

AI总结:

针对MP2RAGE与多TI反转恢复T1测量间的组织相关偏差,本文采用基于图像块的ResNet-18进行校准,在四类组织上显著降低RMSE。

摘要:

典型的定性T1加权磁共振图像会反映扫描仪和协议差异,而定量T1 mapping旨在测量不受这些效应影响的T1。大脑中T1的变化反映脑组织的结构变化。磁化准备双快速采集梯度回波(MP2RAGE)是一种采集协议,与多TI反转恢复(IR)协议相比,它能够以每个层块低得多的扫描时间实现高效T1 mapping。我们采集了四名受试者的、经B1校正且带有额外反转时间的MP2RAGE采集(MP3RAGE)以及多TI选择性反转恢复采集,并对其进行配准。我们对两种MP2RAGE均使用最大后验(MAP)T1估计方法,并与典型的点估计MP2RAGE T1 mapping进行比较,发现MAP MP2RAGE不存在偏差,但MAP MP3RAGE对B1不均匀性敏感。我们证明了MAP MP2RAGE T1估计值与多TI反转恢复T1值之间存在依赖于组织的偏差。为纠正该偏差,我们训练了一个基于图像块的ResNet-18,将MAP MP2RAGE T1估计值校准到多TI IR T1值。在四折交叉验证中,我们的网络显著降低了RMSE(白质:从0.30 ± 0.01秒降至0.11 ± 0.02秒;皮层下灰质:从0.26 ± 0.02秒降至0.10 ± 0.02秒;皮层灰质:从0.36 ± 0.02秒降至0.17 ± 0.03秒)。利用来自两种序列的有限配对训练数据,我们能够减小定量成像方法之间的误差,并通过神经网络将其校准到其中一种协议。

英文摘要:

While typical qualitative T1-weighted magnetic resonance images reflect scanner and protocol differences, quantitative T1 mapping aims to measure T1 independent of these effects. Changes in T1 in the brain reflect structural changes in brain tissue. Magnetization-prepared two rapid acquisition gradient echo (MP2RAGE) is an acquisition protocol that allows for efficient T1 mapping with a much lower scan time per slab compared to multi-TI inversion recovery (IR) protocols. We collect and register B1-corrected MP2RAGE acquisitions with an additional inversion time (MP3RAGE) alongside multi-TI selective inversion recovery acquisitions for four subjects. We use a maximum a posteriori (MAP) T1 estimation method for both MP2RAGE and compare to typical point estimate MP2RAGE T1 mapping, finding no bias from MAP MP2RAGE but a sensitivity to B1 inhomogeneities with MAP MP3RAGE. We demonstrate a tissue-dependent bias between MAP MP2RAGE T1 estimates and the multi-TI inversion recovery T1 values. To correct this bias, we train a patch-based ResNet-18 to calibrate the MAP MP2RAGE T1 estimates to the multi-TI IR T1 values. Across four folds, our network reduces the RMSE significantly (white matter: from 0.30 +/- 0.01 seconds to 0.11 +/- 0.02 seconds, subcortical gray matter: from 0.26 +/- 0.02 seconds to 0.10 +/- 0.02 seconds, cortical gray matter: from 0.36 +/- 0.02 seconds to 0.17 +/- 0.03 seconds). Using limited paired training data from both sequences, we can reduce the error between quantitative imaging methods and calibrate to one of the protocols with a neural network.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑