用于填埋场直流电法勘探的三维混合维代码的灵敏度分析:合成测试

Sensitivity analysis with a 3D mixed-dimensional code for DC geoelectrical investigations of landfills: synthetic tests

Lorenzo Panzeri, Alessio Fumagalli, Laura Longoni, Monica Papini, Diego Arosio

AI总结:

针对填埋场地电勘探灵敏度分析计算成本高的问题,提出将防渗膜近似为二维、电极近似为一维的混合维新方法,验证后发现其对微小衬层损伤检测灵敏度提升显著,后续将优化装置数量并开展试验验证。

摘要:

电阻率层析成像是一种适用于城市生活垃圾填埋场非侵入式监测的技术,但准确的灵敏度分析对于评估地电勘探的有效性与可靠性、合理设计数据采集方案必不可少。通常,垃圾下方会铺设一层薄的高阻膜以防止渗滤液泄漏。在构建灵敏度计算的数值框架时,若考虑电极尤其是防渗膜的实际尺寸,会导致极高的计算成本。\n本研究提出了一种高效数值计算灵敏度的新方法,该方法采用混合维框架,将防渗膜近似为二维对象,将电极近似为一维对象。首先,针对简单四电极阵列与均匀介质的情况,通过解析表达式对代码进行了验证。随后,在简化的填埋场模型中开展测试,模型中一个箱形二维衬层将填埋场主体与周围介质隔开,共使用48个电极。结果表明,沿箱形衬层周边边缘两侧线性布置的电极在检测衬层损伤方面具有良好前景,即使对于直径仅为电极间距六分之一的微小损伤,灵敏度也能提升2-3个数量级。在模拟填埋场与周围介质之间并非由衬层损伤导致的电性连接时,该方法也取得了良好效果。后续工作将评估在现场工作量可控的前提下,获得合适灵敏度所需的最少装置数量,并通过缩尺实验室试验对建模结果进行验证。

英文摘要:

Electrical resistivity tomography is a suitable technique for non-invasive monitoring of municipal solid waste landfills, but accurate sensitivity analysis is necessary to evaluate the effectiveness and reliability of geoelectrical investigations and to properly design data acquisition. Commonly, a thin high-resistivity membrane in placed underneath the waste to prevent leachate leakage. In the construction of a numerical framework for sensitivity computation, taking into account the actual dimensions of the electrodes and, in particular, of the membrane, can lead to extremely high computational costs. In this work, we present a novel approach for numerically computing sensitivity effectively by adopting a mixed-dimensional framework, where the membrane is approximated as a 2D object and the electrodes as 1D objects. The code is first validated against analytical expressions for simple 4-electrode arrays and a homogeneous medium. It is then tested in simplified landfill models, where a 2D box-shaped liner separates the landfill body from the surrounding media, and 48 electrodes are used. The results show that electrodes arranged linearly along both sides of the perimeter edges of the box-shaped liner are promising for detecting liner damage, with sensitivity increasing by 2-3 orders of magnitude, even for damage as small as one-sixth of the electrode spacing in diameter. Good results are also obtained when simulating an electrical connection between the landfill and the surrounding media that is not due to liner damage. The next steps involve evaluating the minimum number of configurations needed to achieve suitable sensitivity with a manageable field effort and validating the modeling results with downscaled laboratory tests.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑