arXiv 2409.09518physics.med-ph
收藏

利用机器人运动平台模拟质子FLASH临床前研究中的大光斑扫描辐射场

Mimicking large spot-scanning radiation fields for proton FLASH preclinical studies with a robotic motion platform

Fada Guan, Dadi Jiang, Xiaochun Wang, Ming Yang, Kiminori Iga, Yuting Li, Lawrence Bronk, Julianna Bronk, Liang Wang, Youming Guo, Narayan Sahoo, David R. Gross… 展开作者

Fada Guan, Dadi Jiang, Xiaochun Wang, Ming Yang, Kiminori Iga, Yuting Li, Lawrence Bronk, Julianna Bronk, Liang Wang, Youming Guo, Narayan Sahoo, David R. Grosshans, Albert C. Koong, Xiaorong R. Zhu, Radhe Mohan

AI总结:

本研究针对质子FLASH临床前研究照射野有限的问题,开发了结合定制机器人运动平台、钨散射体与黄铜准直器的策略,通过自动移动样本增大有效辐射野,验证了定位精度与剂量准确性,为大野质子FLASH临床前研究提供了可行方案。

摘要:

此前,一台基于同步加速器的水平质子束流线(87.2 MeV)已成功调试,可在FLASH和常规剂量率模式下向小照射野和小体积递送辐射剂量。本研究中,我们开发了一种利用定制机器人运动平台自动移动生物样本位置以增大有效辐射野尺寸的策略。束流首先通过薄钨散射体展宽,再经定制黄铜准直器塑形,用于照射96孔板中的细胞/类器官培养物(直径7毫米圆形野)或照射小鼠(1平方厘米方形野)。机器人平台的运动模式以G代码编写,96孔板采用9毫米光斑间距,小鼠照射采用10.6毫米间距。通过自准直激光系统验证了靶定位的准确性。实验条件下的递送剂量通过贴在96孔板或小鼠背部的EBT-XD胶片进行验证。我们的胶片测量剂量分布与蒙特卡罗计算结果吻合良好(一维伽马通过率>95%)。细胞/类器官照射的FLASH剂量率为113.7 Gy/s,小鼠照射的FLASH剂量率为191.3 Gy/s。这些结果表明,该机器人平台可有效增大质子FLASH临床前实验的照射野尺寸。

英文摘要:

Previously, a synchrotron-based horizontal proton beamline (87.2 MeV) was successfully commissioned to deliver radiation doses in FLASH and conventional dose rate modes to small fields and volumes. In this study, we developed a strategy to increase the effective radiation field size using a custom robotic motion platform to automatically shift the positions of biological samples. The beam was first broadened with a thin tungsten scatterer and shaped by customized brass collimators for irradiating cell/organoid cultures in 96-well plates (a 7-mm-diameter circle) or for irradiating mice (1-cm2 square). Motion patterns of the robotic platform were written in G-code, with 9-mm spot spacing used for the 96-well plates and 10.6-mm spacing for the mice. The accuracy of target positioning was verified with a self-leveling laser system. The dose delivered in the experimental conditions was validated with EBT-XD film attached to the 96-well plate or the back of the mouse. Our film-measured dose profiles matched Monte Carlo calculations well (1D gamma pass rate >95%). The FLASH dose rates were 113.7 Gy/s for cell/organoid irradiation and 191.3 Gy/s for mouse irradiation. These promising results indicate that this robotic platform can be used to effectively increase the field size for preclinical experiments with proton FLASH.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑