实用性与精度的结合:集成多通道 PCG 传感器的可穿戴背心用于有效的冠状动脉疾病预筛查
Practicality meets precision: Wearable vest with integrated multi-channel PCG sensors for effective coronary artery disease pre-screening
AI总结:
本文提出集成七通道 PCG 传感器的可穿戴背心,结合 LFCC 特征、SVM 与特征级融合,实现两分钟内无创 CAD 预筛查,准确率达 80.44%。
摘要:
全球死亡和发病的主要原因是心血管疾病(CVD),其中冠状动脉疾病(CAD)是最大的子类别。遗憾的是,心肌梗死或卒中可能成为 CAD 的首发症状,这凸显了早期疾病检测的关键重要性。因此,全球需要一种具有成本效益、无创、可靠且易于使用的系统来预筛查 CAD。既往研究已经探索利用 CAD 产生的微弱杂音,并通过心音图(PCG)信号进行分类。然而,这些研究通常涉及繁琐且不便的数据采集方法,需要精确的受试者准备和环境条件。本研究提出使用一种新型数据采集系统(DAQS),其设计注重简单性和便利性。该 DAQS 将多通道 PCG 传感器集成到一件可穿戴背心中。从穿戴背心、记录信号到脱下背心,整个信号采集过程可在两分钟内完成,且无需专业培训。这体现了大规模筛查的潜力,而当前最先进的流程难以实现这一点。系统采集七路 PCG 信号,其中六路来自胸部,一路来自受试者背部,这是一种新颖的方法。我们的分类方法采用线性频率倒谱系数(LFCC)作为特征,并使用支持向量机(SVM)区分正常心跳与受 CAD 影响的心跳,其表现优于适用于便携式应用的其他低计算量方法。利用特征级融合,多个通道被组合,最优组合取得了最高的受试者级准确率和 F1 分数,分别为 80.44% 和 81.00%,相比表现最佳的单通道提升了 7%。所提出系统的性能指标已被证明具有临床意义。
英文摘要:
The leading cause of mortality and morbidity worldwide is cardiovascular disease (CVD), with coronary artery disease (CAD) being the largest sub-category. Unfortunately, myocardial infarction or stroke can manifest as the first symptom of CAD, underscoring the crucial importance of early disease detection. Hence, there is a global need for a cost-effective, non-invasive, reliable, and easy-to-use system to pre-screen CAD. Previous studies have explored weak murmurs arising from CAD for classification using phonocardiogram (PCG) signals. However, these studies often involve tedious and inconvenient data collection methods, requiring precise subject preparation and environmental conditions. This study proposes using a novel data acquisition system (DAQS) designed for simplicity and convenience. The DAQS incorporates multi-channel PCG sensors into a wearable vest. The entire signal acquisition process can be completed in under two minutes, from fitting the vest to recording signals and removing it, requiring no specialist training. This exemplifies the potential for mass screening, which is impractical with current state-of-the-art protocols. Seven PCG signals are acquired, six from the chest and one from the subject's back, marking a novel approach. Our classification approach, which utilizes linear-frequency cepstral coefficients (LFCC) as features and employs a support vector machine (SVM) to distinguish between normal and CAD-affected heartbeats, outperformed alternative low-computational methods suitable for portable applications. Utilizing feature-level fusion, multiple channels are combined, and the optimal combination yields the highest subject-level accuracy and F1-score of 80.44% and 81.00%, respectively, representing a 7% improvement over the best-performing single channel. The proposed system's performance metrics have been demonstrated to be clinically significant.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。