用于精确径向速度的精确校准光谱——以激光频率梳为参考的碘吸收
Accurate calibration spectra for precision radial velocities -- Iodine absorption referenced by a laser frequency comb
AI总结:
本文利用傅里叶变换光谱仪将激光频率梳的频率精度传递到其未覆盖的碘吸收光谱范围,验证了碘分子吸收模型频率的准确性,为高精度多普勒实验提供了灵活且可优化的波长校准方案。
摘要:
天文光谱仪需要通过空心阴极灯或吸收气体池等光源进行频率校准。激光频率梳(LFCs)能提供最高精度,但面临操作上的挑战。我们的目标是通过参考一个不覆盖相同频率范围的激光频率梳,为分子碘吸收光谱提供精确且准确的频率解。我们使用傅里叶变换光谱仪(FTS)为来自5200–6200Å的碘吸收池和8200Å的激光频率梳的组合光谱生成一致的频率标度。我们使用17,807条梳齿线来确定FTS频率偏移,并将校准后的碘光谱与由分子势模型计算的合成光谱进行比较。在单次扫描中,频率偏移由梳状光谱确定,不确定度约为1 cm s$^{-1}$。梳齿线频率的分布与无线性偏差一致。碘观测结果与模型匹配,偏移小于模型不确定度约1 m s$^{-1}$,这证实了FTS零点在激光频率梳覆盖范围之外仍然有效,并且碘吸收模型的频率是准确的。我们还报告了关于碘模型能量标度的微小系统效应。我们得出结论:傅里叶变换光谱法可以将激光频率梳的精度传递到梳齿原本未覆盖的频率范围。这使我们能够为定制波长校准器的光谱赋予准确的频率标度。这些校准器可以针对单个光谱仪设计在分辨率和光谱带宽方面进行优化,并且对其长期稳定性的要求可以放宽,因为FTS监测可以在运行期间进行。这为高精度多普勒实验的校准源设计和运行提供了灵活性。
英文摘要:
Astronomical spectrographs require frequency calibration through sources like hollow-cathode lamps or absorption-gas cells. Laser frequency combs (LFCs) provide highest accuracy but are facing operational challenges. We aim to provide a precise and accurate frequency solution for the spectrum of molecular iodine absorption by referencing to an LFC that does not cover the same frequency range. We used a Fourier Transform Spectrometer (FTS) to produce a consistent frequency scale for the combined spectrum from an iodine absorption cell at 5200--6200Åand an LFC at 8200Å. We used 17,807 comb lines to determine the FTS frequency offset and compared the calibrated iodine spectrum to a synthetic spectrum computed from a molecular potential model. In a single scan, the frequency offset was determined from the comb spectrum with an uncertainty of $\sim$1 cm s$^{-1}$. The distribution of comb line frequencies is consistent with no deviation from linearity. The iodine observation matches the model with an offset of smaller than the model uncertainties of $\sim$1 m s$^{-1}$, which confirms that the FTS zero point is valid outside the range covered by the LFC, and that the frequencies of the iodine absorption model are accurate. We also report small systematic effects regarding the iodine model's energy scale. We conclude that Fourier Transform Spectrometry can transfer LFC accuracy into frequency ranges not originally covered by the comb. This allows us to assign accurate frequency scales to the spectra of customized wavelength calibrators. The calibrators can be optimized for individual spectrograph designs regarding resolution and spectral bandwidth, and requirements on their long-term stability are relaxed because FTS monitoring can be performed during operation. This provides flexibility for the design and operation of calibration sources for high-precision Doppler experiments.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。