arXiv 2409.02613physics.acc-ph
收藏

μ子对撞机直线冷却通道的性能与容差研究

Performance and tolerance study of the rectilinear cooling channel for a muon collider

Ruihu Zhu, Chris Rogers, Jiancheng Yang, He Zhao, Cheng Guo, Jiangdong Li

AI总结:

本文针对μ子对撞机初始六维冷却需求,提出含附加偶极磁铁的直线冷却通道概念设计,给出通用设计方法,并研究π模射频腔及场误差对冷却性能的影响。

摘要:

μ子对撞机有潜力成为探索粒子物理前沿的强大工具。为了达到高亮度,μ子束的六维发射度需要降低几个数量级。μ子对撞机的冷却过程包括两个部分:初始六维冷却和最终横向冷却。本文聚焦于前者,并提出了一种带有附加偶极磁铁的直线冷却通道的概念设计。在本文中,我们首先介绍了一种设计直线冷却通道的通用方法。随后,我们应用该方法在束团合并系统前后分别设计了两个直线冷却通道。此外,我们还研究了采用π模射频腔对冷却性能的影响,并考虑了磁场和射频场误差的影响。

英文摘要:

The muon collider has the potential to be a powerful tool for the exploration of frontiers in particle physics. In order to reach high luminosity, the 6D emittance of the muon beam needs to be reduced by several orders of magnitude. The cooling process for a muon collider involves two parts; initial six-dimensional cooling and final transverse cooling. This paper focuses on the former and proposes a conceptual design of the rectilinear cooling channel with additional dipole magnets. In this paper, we first introduce a general method for designing the rectilinear cooling channel. Subsequently, we apply this method to develop two rectilinear cooling channels before and after a bunch merging system. Furthermore, we investigate the impact on cooling performance by employing $π$-mode RF cavities and considering the effect of errors in the magnetic and RF fields.