具有主动响应的厚壁纤维增强动脉的生长、重塑与损伤建模:应用于脑血管痉挛及其治疗

Modelling Growth, Remodelling and Damage of a Thick-walled Fibre-reinforced Artery with Active Response: Application to Cerebral Vasospasm and Treatment

Giulia Pederzani, Andrii Grytsan, Alfons G. Hoekstra, Anne M. Robertson, Paul N. Watton

AI总结:

本文提出一种三维有限元基于速率的约束混合物模型,模拟脑血管痉挛及支架取栓治疗,揭示动脉直径和壁厚对治疗效果的影响,为个性化治疗提供计算工具。

摘要:

脑血管痉挛是脑动脉的持续性收缩,是动脉瘤性蛛网膜下腔出血后存活住院患者发病和死亡的首要原因。近期发现支架取栓器可成功治疗该疾病,这一发现挑战了细胞外基质损伤是必要条件的观点。我们应用三维有限元基于速率的约束混合物模型(rb-CMM)来模拟血管痉挛、重塑及支架治疗。动脉被建模为承受生理压力和轴向拉伸的厚壁纤维增强约束混合物。该模型考虑了胶原纤维稳态拉伸分布、血管平滑肌细胞(VSMC)主动响应、重塑和损伤。在模拟血管痉挛及随后动脉重塑至新的稳态之后,我们模拟了使用常用支架取栓器进行的治疗。我们进行了参数研究,以考察动脉直径和壁厚如何影响支架治疗的成功率。模型对机械解除收缩所需压力的预测与支架取栓器一致。与临床观察相符,我们的模型预测支架取栓器在直径不超过3mm的动脉中往往有效,但在较大动脉中失败。动脉壁厚度的变化显著影响支架压力需求。我们开发了一种新颖的rb-CMM,该模型考虑了VSMC主动响应、重塑和损伤。与临床观察一致,模拟预测支架取栓器可以机械解除血管痉挛。此外,考虑患者的动脉特性对于预测支架成功的可能性非常重要。这一计算机模拟工具有潜力支持临床决策,并指导用于血管痉挛个性化治疗的专用支架的开发和评估。

英文摘要:

Cerebral vasospasm, a prolonged constriction of cerebral arteries, is the first cause of morbidity and mortality for patients who survive hospitalisation after aneurysmal subarachnoid haemorrhage. The recent finding that stent-retrievers can successfully treat the disease has challenged the viewpoint that damage to the extracellular matrix is necessary. We apply a 3D finite element rate-based constrained mixture model (rb-CMM) to simulate vasospasm, remodelling and treatment with stents. The artery is modelled as a thick-walled fibre-reinforced constrained mixture subject to physiological pressure and axial stretch. The model accounts for distributions of collagen fibre homeostatic stretches, VSMC active response, remodelling and damage. After simulating vasospasm and subsequent remodelling of the artery to a new homeostatic state, we simulate treatment with commonly available stent-retrievers. We perform a parameter study to examine how arterial diameter and thickness affect the success of stent treatment. The model predictions on the pressure required to mechanically resolve the constriction are consistent with stent-retrievers. In agreement with clinical observations, our model predicts that stent-retrievers tend to be effective in arteries of up to 3mm diameter, but fail in larger ones. Variations in arterial wall thickness significantly affect stent pressure requirements. We have developed a novel rb-CMM that accounts for VSMC active response, remodelling and damage. Consistently with clinical observations, simulations predict that stent-retrievers can mechanically resolve vasospasm. Moreover, accounting for a patient's arterial properties is important for predicting likelihood of stent success. This in silico tool has the potential to support clinical decision-making and guide the development and evaluation of dedicated stents for personalised treatment of vasospasm.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑