arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2408.16413physics.med-phphysics.optics
收藏

化学计量学辅助的表面增强拉曼光谱法对血液中GH和TE激素的检测与定量

Chemometrics-aided Surface-enhanced Raman spectrometric detection and quantification of GH and TE hormones in blood

Annah M. Ondieki, Zephania Birech, Kenneth A. Kaduki, Peter W. Mwangi, Moses Juma, Boniface M. Chege

AI总结:

本研究结合SERS与ANN模型,实现了SD大鼠血液中GH和TE激素的快速高精度检测与定量,为检测外源性运动兴奋剂提供了新方法。

摘要:

本研究探索了使用表面增强拉曼光谱(SERS)结合人工神经网络(ANN)模型来检测和定量Sprague Dawley(SD)大鼠血液中的生长激素(GH)和睾酮(TE)。使用785 nm激光激发,从注射了GH、TE、两种激素均注射以及未注射对照组的SD大鼠血液样本中记录了SERS光谱。样本与在蒸馏水中合成的银纳米颗粒(AgNPs)混合,涂在显微镜载玻片上并风干。所得的SERS光谱显示出相似的轮廓,但强度变化取决于激素,在658、798、878、914、932、1064、1190、1354、1410和1658 cm-1处显示出特定谱带。PCA分析表明,以1378 cm-1为中心的谱带(所有组)、658和1614 cm-1(注射GH的大鼠)以及其他谱带在不同激素组合下表现出时间依赖性强度变化。这些变化反映了激素注射引起的微妙生化变化。使用添加了不同激素浓度的血液的六个PCA分数训练的ANN模型显示出高准确度,决定系数大于87.71%,均方根误差(RMSE)低于0.6436。注射大鼠体内的激素水平最初升高随后下降,这一趋势由ELISA试剂盒证实。尽管ELISA和SERS产生了相似的结果,但SERS具有快速分析(约两分钟)、样品制备简单、样品体积小和对激素非特异性等优势。这表明SERS结合ANN模型可用于检测外源性运动兴奋剂。这些发现扩展了SERS在运动科学、临床诊断和生物医学研究中的潜在应用。

英文摘要:

This work explores the use of Surface-Enhanced Raman Spectroscopy (SERS) combined with artificial neural network (ANN) models to detect and quantify growth hormone (GH) and testosterone (TE) in the blood of Sprague Dawley (SD) rats. SERS spectra were recorded from blood samples of SD rats injected with GH, TE, both hormones, and non-injected controls using 785 nm laser excitation. The samples were mixed with silver nanoparticles (AgNPs) synthesized in distilled water, applied onto a microscope slide, and air-dried. The resulting SERS spectra displayed similar profiles with intensity variations depending on the hormone, revealing specific bands at 658, 798, 878, 914, 932, 1064, 1190, 1354, 1410, and 1658 cm-1. PCA analysis indicated time-dependent intensity changes in bands centered around 1378 (all groups), 658 and 1614 cm-1 (GH-injected rats), and others for different hormone combinations. These variations reflect subtle biochemical changes induced by hormone injections. The ANN models, trained with six PCA scores of blood spiked with various hormone concentrations, showed high accuracy, with coefficients of determination greater than 87.71% and low root mean square error (RMSE) values below 0.6436. The hormone levels in injected rats increased initially and later declined, a trend confirmed by ELISA kits. Although ELISA and SERS produced similar results, SERS offered advantages such as rapid analysis (about two minutes), simple sample preparation, small sample volumes, and non-specificity to hormones. This suggests that SERS, combined with ANN models, could be used to detect exogenous sports dopants. These findings expand the potential applications of SERS in sports science, clinical diagnostics, and biomedical research.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑