ARDS患者基于物理模型的区域肺力学预测:一项验证研究

Patient-specific prediction of regional lung mechanics in ARDS patients with physics-based models: a validation study

Ebenbuild GmbH(Ebenbuild有限公司);Institute for Computational Mechanics, Department of Engineering Physics and Computation, TUM School of Engineering and Design, Technical University of Munich(慕尼黑工业大学工程与设计学院工程物理与计算系计算力学研究所);Department of Anesthesiology and Intensive Care Medicine, University Hospital Schleswig-Holstein(什未因-荷尔斯泰因大学医院麻醉与重症医学科)
Maximilian Rixner, Maximilian Ludwig, Matthias Lindner, Inéz Frerichs, Armin Sablewski, Karl-Robert Wichmann, Max-Carl Wachter, Kei W. Müller, Dirk Schädler, Wo… 展开作者

Maximilian Rixner, Maximilian Ludwig, Matthias Lindner, Inéz Frerichs, Armin Sablewski, Karl-Robert Wichmann, Max-Carl Wachter, Kei W. Müller, Dirk Schädler, Wolfgang A. Wall, Jonas Biehler, Tobias Becher

AI总结:

本研究利用基于物理的计算模型,针对ARDS患者预测区域肺力学,通过验证显示模型能准确反映患者局部肺状态,为个性化通气设置提供依据。

摘要:

机械通气的通风设置选择对患者预后有重大影响,但为个体患者确定最佳通气设置仍极具挑战性,这主要是由于固有地存在患者间和患者内的病理生理变异。在本验证研究中,我们证明了针对个体患者的基于物理的计算肺模型能够解决这种变异,使我们能够预测机械通气过程中病理影响的肺部局部状态。对于七名接受有创机械通气的ARDS患者,使用胸部CT扫描和通气数据创建了基于物理的、个体化的肺模型。通过数值求解病理肺与呼吸机施加的气道压力和流量的相互作用,我们为每位患者预测了时间依赖性和异质性的肺局部状态,并将其与床旁监测使用电阻抗断层扫描获得的区域通气进行比较。数值模拟与实验数据之间取得了极好的一致,模型预测的前后向通气轮廓与临床参考数据的皮尔逊相关系数达到96%。即使考虑整个横向胸腔横截面内和整个动态通气范围内的区域通气,也实现了平均相关性超过81%和平均均方误差小于15%。本首次系统验证研究的结果表明,计算模型能够提供临床相关的信息,从而为基于个体解剖和病理生理的真正患者特异性通气设置选择打开大门。

英文摘要:

The choice of lung protective ventilation settings for mechanical ventilation has a considerable impact on patient outcome, yet identifying optimal ventilatory settings for individual patients remains highly challenging due to the inherent inter- and intra-patient pathophysiological variability. In this validation study, we demonstrate that physics-based computational lung models tailored to individual patients can resolve this variability, allowing us to predict the otherwise unknown local state of the pathologically affected lung during mechanical ventilation. For seven ARDS patients undergoing invasive mechanical ventilation, physics-based, patient-specific lung models were created using chest CT scans and ventilatory data. By numerically resolving the interaction of the pathological lung with the airway pressure and flow imparted by the ventilator, we predict the time-dependent and heterogeneous local state of the lung for each patient and compare it against the regional ventilation obtained from bedside monitoring using Electrical Impedance Tomography. Excellent agreement between numerical simulations and experimental data was obtained, with the model-predicted anteroposterior ventilation profile achieving a Pearson correlation of 96% with the clinical reference data. Even when considering the regional ventilation within the entire transverse chest cross-section and across the entire dynamic ventilation range, an average correlation of more than 81% and an average root mean square error of less than 15% were achieved. The results of this first systematic validation study demonstrate the ability of computational models to provide clinically relevant information and thereby open the door for a truly patient-specific choice of ventilator settings on the basis of both individual anatomy and pathophysiology.