AI总结:

本文提出结合数据草图与微调Vision Transformer的方法检测CT医学影像分布漂移,在乳腺X线案例中准确率达99.11%,并对微小噪声高度敏感。

摘要:

分布漂移检测在医学应用中十分重要,因为它有助于通过识别可能影响机器学习模型预测结果的底层数据分布变化来确保模型的准确性和可靠性。然而,当前方法在检测漂移方面存在局限性,例如,纳入异常数据集可能导致不公平的比较。本文提出了一种准确且灵敏的方法,通过利用数据草图(data-sketching)和微调技术来检测CT扫描医学影像中的分布漂移。我们开发了一个鲁棒的基线库模型用于实时异常检测,从而能够高效地比较传入影像并识别异常。此外,我们微调了一个预训练的Vision Transformer模型以提取相关特征,并以乳腺X线摄影(mammography)作为案例研究,将模型准确率显著提升至99.11%。结合数据草图和微调,我们的特征提取评估表明,相似数据集之间的余弦相似度分数带来了更大的改进,从约50%提升至99.1%。最后,灵敏度评估显示,我们的解决方案对即使1%的椒盐噪声和斑点噪声也高度敏感,并且对光照噪声不敏感(例如,光照条件对数据漂移没有影响)。所提出的方法为在动态临床环境中保持诊断模型的准确性提供了一种可扩展且可靠的解决方案。

英文摘要:

Distributional drift detection is important in medical applications as it helps ensure the accuracy and reliability of models by identifying changes in the underlying data distribution that could affect the prediction results of machine learning models. However, current methods have limitations in detecting drift, for example, the inclusion of abnormal datasets can lead to unfair comparisons. This paper presents an accurate and sensitive approach to detect distributional drift in CT-scan medical images by leveraging data-sketching and fine-tuning techniques. We developed a robust baseline library model for real-time anomaly detection, allowing for efficient comparison of incoming images and identification of anomalies. Additionally, we fine-tuned a pre-trained Vision Transformer model to extract relevant features, using mammography as a case study, significantly enhancing model accuracy to 99.11%. Combining with data-sketches and fine-tuning, our feature extraction evaluation demonstrated that cosine similarity scores between similar datasets provide greater improvements, from around 50% increased to 99.1%. Finally, the sensitivity evaluation shows that our solutions are highly sensitive to even 1% salt-and-pepper and speckle noise, and it is not sensitive to lighting noise (e.g., lighting conditions have no impact on data drift). The proposed methods offer a scalable and reliable solution for maintaining the accuracy of diagnostic models in dynamic clinical environments.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑