arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2408.08173astro-ph.IM
收藏

利用混合单光子计数探测器的超快强度干涉仪的在轨演示

On-sky demonstration of an ultra-fast intensity interferometry instrument utilizing hybrid single photon counting detectors

Verena G. Leopold, Sebastian Karl, Jean-Pierre Rivet, Joachim von Zanthier

AI总结:

本研究开发了一款用于1米级光学望远镜的超快单光子计数强度干涉仪,利用混合光子探测器和恒定分数鉴别器优化时间分辨率,成功测量了三颗明亮A型恒星的光子聚束现象,观测相干时间与预期及实验室值高度吻合,为高分辨率空间强度干涉测量提供了新途径。

摘要:

强度干涉测量是一种复兴的天文技术,用于在可见光波段进行高角分辨率研究,极大地受益于近期(单)光子探测仪器的改进。我们为1米级光学望远镜开发了一款超快、单光子计数且高度稳定的强度干涉仪。该仪器在天空上记录预期的恒星光子速率,并达到了在实验室中测量的时间相干时间。此外,该仪器的所有组件,尤其是光子探测硬件,均可通过目前正在开发的定制硬件轻松升级。准直望远镜的输出通过中心波长405纳米处2纳米的超窄带通进行光谱滤波。我们使用混合光子探测器(HPDs)进行单光子探测,并使用恒定分数鉴别器(CFD)进行信号调理。使用时间数字转换器(TDC)进行时间戳标记。HPDs和CFDs的组合针对大有效面积和高时间分辨率进行了优化。我们成功测量了三颗明亮A型恒星——织女星、牛郎星和天津四的光子聚束,观测地点位于法国南部Calern天文台C2PU的1.04米Omicron望远镜。在所有情况下,观测到的相干时间均与预计算期望值及先前实验室测试中测得的值高度吻合。我们在望远镜上获得了先前估算的光子计数率,并实现了星光与探测器的高稳定耦合。利用基于多通道板放大的新型大面积单光子探测器,在1米直径级望远镜上,仅需一夜观测时间即可对明亮恒星开展高分辨率空间强度干涉测量实验。

英文摘要:

Intensity interferometry is a reemerging astronomical technique for performing high angular resolution studies at visible wavelengths, benefiting immensely from the recent improvements in (single) photon detection instrumentation. We developed an ultra-fast, single photon counting and highly stable intensity interferometry instrument for 1 m class optical telescopes. The instrument records on sky the expected stellar photon rates and reaches the temporal coherence times as measured in the laboratory. In addition, all components, especially the photon detection hardware, of the instrument are easily upgradeable with custom hardware currently being developed. The collimated telescope output is spectrally filtered via an ultra narrow band pass of 2 nm at a central wavelength of 405 nm. We use hybrid photon detectors (HPDs) for single photon detection and a constant fraction discriminator (CFD) for signal conditioning. A time to digital converter (TDC) is used for time stamping. The combination of HPDs and CFDs is optimized for large active area and high timing resolution. We successfully measured photon bunching of three bright A-type stars - Vega, Altair and Deneb at the 1.04 m Omicron telescope of C2PU at the Calern Observatory in the south of France. In all cases the observed coherence time fits well to both the pre-calculated expectations as well as the values measured in preceding laboratory tests. We obtained the previously estimated photon count rates at the telescope and achieved highly stable coupling of the star light to the detectors. Utilizing a new class of large area single photon detectors based on multichannel plate amplification, high resolution spatial intensity interferometry experiments are within reach at 1 m diameter class telescopes within one night of observation time for bright stars.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑