摘要:

恒温控制负荷在停电后恢复供电时会对电力需求产生显著影响,这一现象被称为冷负荷启动(cold load pick-up,CLPU)。主动管理CLPU正成为配电系统运营商推迟网络升级、加快停电后用户复电速度的重要工具。主动管理CLPU所需的一项核心功能是对其进行多尺度预测。智能计量设备的广泛部署也为数据驱动的负荷建模与预测开辟了新机遇。本文提出了一种利用带时间戳的局部负荷测量值,在用户侧估计CLPU的方法。该方法采用自回归积分滑动平均(Auto-Regressive Integrated Moving Average,ARIMA)模型,对停电期间的短期损失能耗进行预测。预测以小时为单位开展,用于估计持续时间最长达数小时的停电后潜在需要恢复的电量。此外,为适配不断变化的用户行为与天气情况,模型阶数会动态调整。本文基于50户居民用户为期一年的实际智能电表测量值开展了仿真实验,仿真结果通过居民负荷物理建模得到验证,且与基于ARIMA的预测结果吻合度较高。研究还将该方法的准确率与执行速度和长短期记忆网络(Long Short Term Memory Network,LSTM)、霍尔特-温特斯指数平滑(Holt-Winters Exponential Smoothing,HWES)等其他主流时间序列预测方法进行了对比,结果表明基于ARIMA的预测在准确率和计算速度两方面均表现更优。

英文摘要:

Thermostatically-controlled loads have a significant impact on electricity demand after service is restored following an outage, a phenomenon known as cold load pick-up (CLPU). Active management of CLPU is becoming an essential tool for distribution system operators who seek to defer network upgrades and speed up post-outage customer restoration. One key functionality needed for actively managing CLPU is its forecast at various scales. The widespread deployment of smart metering devices is also opening up new opportunities for data-driven load modeling and forecast. In this paper, we propose an approach for customer-side estimation of CLPU using time-stamped local load measurements. The proposed method uses Auto-Regressive Integrated Moving Average (ARIMA) modeling for short-term foregone energy consumption forecast during an outage. Forecasts are made on an hourly basis to estimate the energy to potentially recover after outages lasting up to several hours. Moreover, to account for changing customer behavior and weather, the model order is adjusted dynamically. Simulation results based on actual smart meter measurements are presented for 50 residential customers over the duration of one year. These results are validated using physical modeling of residential loads and are shown to match well the ARIMA-based forecasts. Additionally, accuracy and execution speed has been compared with other state-of-the-art approaches for time-series forecasting including Long Short Term Memory Network (LSTM) and Holt-Winters Exponential Smoothing (HWES). ARIMA-based forecast is found to offer superior performance both in terms of accuracy and computation speed.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑