arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2408.04777eess.IVcs.CV
收藏

基于深度学习的无监督域自适应:采用统一模型利用多中心双参数MRI数据集进行前列腺病变检测

Deep Learning-based Unsupervised Domain Adaptation via a Unified Model for Prostate Lesion Detection Using Multisite Bi-parametric MRI Datasets

Siemens Healthineers(西门子医疗);Vanderbilt University(范德堡大学);Radboud University Medical Center(拉德堡德大学医学中心);New York University(纽约大学);Universitätsspital Basel(巴塞尔大学医院);Charité, Universitätsmedizin Berlin(柏林夏里特医学院);Patero Clinic(帕特罗诊所);Eunpyeong St. Mary's Hospital, Catholic University of Korea(韩国天主教大学恩平圣玛丽医院);Changhai Hospital of Shanghai(上海长海医院);Diagnostikum Graz Süd-West(格拉茨西南诊断中心);Loyola University Medical Center(洛约拉大学医学中心);Oregon Health and Science University(俄勒冈健康与科学大学);Massachusetts General Hospital(麻省总医院)
Hao Li, Han Liu, Heinrich von Busch, Robert Grimm, Henkjan Huisman, Angela Tong, David Winkel, Tobias Penzkofer, Ivan Shabunin, Moon Hyung Choi, Qingsong Yang, … 展开作者

Hao Li, Han Liu, Heinrich von Busch, Robert Grimm, Henkjan Huisman, Angela Tong, David Winkel, Tobias Penzkofer, Ivan Shabunin, Moon Hyung Choi, Qingsong Yang, Dieter Szolar, Steven Shea, Fergus Coakley, Mukesh Harisinghani, Ipek Oguz, Dorin Comaniciu, Ali Kamen, Bin Lou

AI总结:

本研究提出一种基于统一生成模型的无监督域自适应方法,将多中心不同b值的前列腺DWI图像转换为PI-RADS推荐风格,显著提升了多中心前列腺癌检测的监督学习模型性能,尤其对采集协议偏差大的图像效果更突出。

摘要:

我们的假设是,通过统一模型生成的扩散加权图像实现的无监督域自适应(UDA),为提升多中心前列腺病变检测中监督学习模型的性能提供了一种有前景且可靠的策略,尤其是在存在多种b值的情况下。这项回顾性研究纳入了来自9个不同成像中心的5150名患者的数据(共14191个样本)。我们开发了一种采用统一生成模型的新型UDA方法,用于多中心前列腺癌(PCa)检测。该方法将扩散加权成像(DWI)采集结果——包括表观扩散系数(ADC)图以及采用不同b值采集的单张DW图像——转换为与前列腺成像报告和数据系统(PI-RADS)指南推荐b值下采集的图像风格对齐。生成的ADC图和DW图像将替代原始图像用于PCa检测。研究采用包含1692个测试病例(2393个样本)的独立数据集进行评估,以受试者工作特征曲线下面积(AUC)作为主要指标,并通过自助法(bootstrapping)进行统计分析。对于所有测试病例,在PI-RADS评分≥3的PCa病变检测中,基线监督学习(SL)方法和UDA方法的AUC值分别为0.73和0.79(p<.001);在PI-RADS评分≥4的PCa病变检测中,二者AUC值分别为0.77和0.80(p<.001)。在处于最不利图像采集设置下的361个测试病例中,PI-RADS评分≥3的病变检测里,基线SL和UDA的AUC值分别为0.49和0.76(p<.001);PI-RADS评分≥4的病变检测里,二者AUC值分别为0.50和0.77(p<.001)。结果表明,所提出的结合生成图像的UDA方法,在包含不同b值的多中心数据集上提升了SL方法的PCa病变检测性能,尤其适用于采集参数与PI-RADS推荐的DWI协议存在显著偏差(例如b值极高)的图像。

英文摘要:

Our hypothesis is that UDA using diffusion-weighted images, generated with a unified model, offers a promising and reliable strategy for enhancing the performance of supervised learning models in multi-site prostate lesion detection, especially when various b-values are present. This retrospective study included data from 5,150 patients (14,191 samples) collected across nine different imaging centers. A novel UDA method using a unified generative model was developed for multi-site PCa detection. This method translates diffusion-weighted imaging (DWI) acquisitions, including apparent diffusion coefficient (ADC) and individual DW images acquired using various b-values, to align with the style of images acquired using b-values recommended by Prostate Imaging Reporting and Data System (PI-RADS) guidelines. The generated ADC and DW images replace the original images for PCa detection. An independent set of 1,692 test cases (2,393 samples) was used for evaluation. The area under the receiver operating characteristic curve (AUC) was used as the primary metric, and statistical analysis was performed via bootstrapping. For all test cases, the AUC values for baseline SL and UDA methods were 0.73 and 0.79 (p<.001), respectively, for PI-RADS>=3, and 0.77 and 0.80 (p<.001) for PI-RADS>=4 PCa lesions. In the 361 test cases under the most unfavorable image acquisition setting, the AUC values for baseline SL and UDA were 0.49 and 0.76 (p<.001) for PI-RADS>=3, and 0.50 and 0.77 (p<.001) for PI-RADS>=4 PCa lesions. The results indicate the proposed UDA with generated images improved the performance of SL methods in multi-site PCa lesion detection across datasets with various b values, especially for images acquired with significant deviations from the PI-RADS recommended DWI protocol (e.g. with an extremely high b-value).