arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2408.04299cs.CV
收藏

呼吸差分:通过术前与术中图像融合增强肺部热消融评估

Respiratory Differencing: Enhancing Pulmonary Thermal Ablation Evaluation Through Pre- and Intra-Operative Image Fusion

Beijing Institute of Respiratory Medicine(北京呼吸病研究所);Beijing Chao Yang Hospital(北京朝阳医院);Capital Medical University(首都医科大学);First Imaging Medical Equipment(第一影像医疗设备公司);School of Computer Science and Engineering, Southeast University(东南大学计算机科学与工程学院)

Wan Li, Wei Li, Moheng Rong, Yutao Rao, Hui Tang, Yudong Zhang, Feng Wang

AI总结:

本文提出Respiratory Differencing系统,通过多阶段配准融合术前与术中CT图像并生成差分图像和定量指标,辅助医生更准确地评估肺部热消融效果,在35例临床研究中显著优于传统主观评估。

摘要:

CT图像引导的热消融被广泛用于肺癌治疗;然而,随访数据表明,医生对术中图像的主观评估常常高估消融效果,可能导致治疗不彻底。为应对这些挑战,我们开发了Respiratory Differencing,一种新型术中CT图像辅助系统,旨在改进消融评估。该系统首先在术前CT图像中分割肿瘤区域,然后采用多阶段配准流程将这些图像与相应的术中或术后图像对齐,以补偿呼吸形变和治疗引起的变化。该系统提供两项关键输出,帮助医生评估术中消融效果。第一,通过从术中图像中减去配准后的术前图像生成差分图像,从而直接可视化和定量比较治疗前后的差异。这些差分图像使医生能够评估肿瘤与消融区的相对位置,即使在消融后图像中肿瘤已不再可见,也能改善对消融有效性的主观评估。第二,该系统提供一种定量指标,用于衡量肿瘤区域与治疗区域之间的差异,为消融的整体疗效提供数值化评估。这一开创性系统补偿了复杂的肺部形变,并整合了术前与术中影像数据,增强了癌症消融治疗的质量控制。一项涉及35例临床病例的随访研究表明,我们的系统在治疗期间或治疗后立即识别消融不足病例方面显著优于传统主观评估,凸显了其在改善临床决策和患者预后方面的潜力。

英文摘要:

CT image-guided thermal ablation is widely used for lung cancer treatment; however, follow-up data indicate that physicians' subjective assessments of intraoperative images often overestimate the ablation effect, potentially leading to incomplete treatment. To address these challenges, we developed \textit{Respiratory Differencing}, a novel intraoperative CT image assistance system aimed at improving ablation evaluation. The system first segments tumor regions in preoperative CT images and then employs a multi-stage registration process to align these images with corresponding intraoperative or postoperative images, compensating for respiratory deformations and treatment-induced changes. This system provides two key outputs to help physicians evaluate intraoperative ablation. First, differential images are generated by subtracting the registered preoperative images from the intraoperative ones, allowing direct visualization and quantitative comparison of pre- and post-treatment differences. These differential images enable physicians to assess the relative positions of the tumor and ablation zones, even when the tumor is no longer visible in post-ablation images, thus improving the subjective evaluation of ablation effectiveness. Second, the system provides a quantitative metric that measures the discrepancies between the tumor area and the treatment zone, offering a numerical assessment of the overall efficacy of ablation.This pioneering system compensates for complex lung deformations and integrates pre- and intra-operative imaging data, enhancing quality control in cancer ablation treatments. A follow-up study involving 35 clinical cases demonstrated that our system significantly outperforms traditional subjective assessments in identifying under-ablation cases during or immediately after treatment, highlighting its potential to improve clinical decision-making and patient outcomes.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑