arXiv 2408.02703physics.med-phphysics.app-phphysics.ins-det
收藏

自校准智能 OCT-SLO 系统

Self-calibrating Intelligent OCT-SLO System

Mayank Goswami

AI总结:

本文提出一种与样本无关的三维自校准方法,并基于全自动 AI 驱动的 OCT-SLO 混合系统实现智能光学对准与对比度调节,相比传统信噪比方法性能提升 200% 且速度快 130%,在多个光谱下实现微米级分辨率成像,适用于光动力成像治疗。

摘要:

一种独特的、与样本无关的三维自校准方法,在一套独特的光学相干断层扫描与多光谱扫描激光检眼镜(OCT-SLO)混合系统上进行了测试。通过所提出的新型全自动人工智能驱动系统设计,操作者的视觉认知被计算机视觉所取代。在预先指定的感兴趣区域上,实现了针对样本的光束自动对比度调节。该人工智能模型通过定量估计预先指定的特征,推断红外、荧光和可见光谱的光学对准。不过,所测试的方法具有足够的灵活性,可以利用任何合适的人工智能模型。与经典的基于信噪比驱动的自动化方法进行相对比较,结果表明后者比人工智能驱动方法性能差 200%,且速度慢 130%。该系统的最佳空间分辨率被确定为:(a)在玻璃珠仿眼模型中轴向方向为 2.41 微米,在小鼠视网膜中轴向方向为 0.76 微米、标准差 0.46 微米;(b)在冠状面、额面或 x-y 平面上,对于所有三个光谱(即 488 nm、840 nm 以及 520 至 550 nm 发射光)均优于每毫米 228 线对(lp/mm)或 2 微米。智能自动化通过便于操作以实现快速眼部成像和更高精度,降低了发生冷性白内障(尤其是在小鼠成像中)的可能性,并减少了手动对准过程中因延迟而给患者带来的不适。这种自动化的新型台式紧凑系统能够在三个不同光谱下为动态样本轮廓提供真正的功能性三维图像,这对于光动力成像治疗尤其有用。

英文摘要:

A unique sample independent 3D self calibration methodology is tested on a unique optical coherence tomography and multi-spectral scanning laser ophthalmoscope (OCT-SLO) hybrid system. Operators visual cognition is replaced by computer vision using the proposed novel fully automatic AI-driven system design. Sample specific automatic contrast adjustment of the beam is achieved on the pre-instructed region of interest. The AI model deduces infrared, fluorescence, and visual spectrum optical alignment by estimating pre-instructed features quantitatively. The tested approach, however, is flexible enough to utilize any apt AI model. Relative comparison with classical signal-to-noise-driven automation is shown to be 200 percent inferior and 130 percent slower than the AI-driven approach. The best spatial resolution of the system is found to be (a) 2.41 microns in glass bead eye phantom, 0.76 with STD 0.46 microns in the mouse retina in the axial direction, and (b) better than 228 line pair per millimeter (lp per mm) or 2 microns for all three spectrums, i.e., 488 nm, 840 nm, and 520 to 550 nm emission in coronal, frontal or x-y plane. Intelligent automation reduces the possibility of developing cold cataracts (especially in mouse imaging) and patient-associated discomfort due to delay during manual alignment by facilitating easy handling for swift ocular imaging and better accuracy. The automatic novel tabletop compact system provides true functional 3D images in three different spectrums for dynamic sample profiles. This is especially useful for photodynamic imaging treatment.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑