arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2407.14493astro-ph.IM
收藏

用于探测器抖动和柔性补偿的精密低温定位平台

A Precision Cryogenic Positioning Stage for Detector Dithering and Flexure Compensation

Stephen A. Smee, Stephen C. Hope, Randolph P. Hammond, Leon Aslan, Robert H. Barkhouser, Katherine G. Smee, Andrea Bianco, Christoph Birk, Maren Cosens, Aidan C… 展开作者

Stephen A. Smee, Stephen C. Hope, Randolph P. Hammond, Leon Aslan, Robert H. Barkhouser, Katherine G. Smee, Andrea Bianco, Christoph Birk, Maren Cosens, Aidan C. Gray, Michele Frangiamore, Albert C. Harding, Tyson Hare, Daniel D. Kelson, Gerrad Killion, Nicholas P. Konidaris, Alicia Lanz, Jacob McCloskey, Andrew B. Newman, Solange Ramirez, Gwen C. Rudie, Andrea Vanella, Jason E. Williams

AI总结:

本文介绍用于MIRMOS光谱仪的精密低温X-Y定位平台,实现探测器抖动与柔性补偿,采用压电驱动和磁阻反馈,在120K下提供高精度无间隙运动。

摘要:

本文介绍了一种用于探测器抖动和柔性补偿的精密X-Y平台的设计与技术进展。该平台正在开发中,将用于麦哲伦红外多目标光谱仪(MIRMOS)。MIRMOS是一台大型内史密斯安装式光谱仪,包含安装在长低温光学平台上的折射、反射和衍射光学元件组合。该仪器使用五个科学相机,每个相机配备定制X-Y平台以控制相机内探测器平面内位置,既提供改进采样的抖动能力,又提供柔性补偿以校正因仪器重力变化操作导致的图像运动。该平台设计在120K温度下运行,将精确控制探测器在两个正交自由度上的位置,并具有手动微调功能以设置探测器的倾斜、俯仰和活塞位置。压电驱动的柔性平台提供高分辨率无间隙探测器运动,并沿光路方向非常紧凑,使相机长度最小化。磁阻桥在每个自由度提供位置反馈,大大减少了压电致动器中常见的迟滞现象。该系统设计为开环运行,使用以内史密斯旋转器角度为键的查找表进行柔性控制。本文介绍并讨论了该平台的光机设计、电气控制系统以及早期原型工作的当前性能结果。

英文摘要:

This paper presents the design and technical progress of a precision X-Y stage for detector dithering and flexure compensation. The stage is being developed for use in the Magellan InfraRed Multi-Object Spectrograph, MIRMOS. MIRMOS is a very large Nasmyth mounted spectrograph containing a combination of refractive, reflective and diffractive optics mounted on a long cryogenic optical bench. The instrument utilizes five science cameras, each having a custom x-y stage to control the in-plane detector position within each camera, providing both dithering capability for improved sampling, and flexure compensation to correct for image motion that results from the gravity variant operation of the instrument. Designed to operate at 120~K, the stage will accurately control detector position in two orthogonal degrees of freedom, and have manual fine adjustment features to set detector tip, tilt and piston. The piezo-driven flexure stage provides high-resolution backlash-free motion of the detector and is very compact along the optical path, keeping camera length to a minimum. A magnetoresistive bridge provides position feedback in each degree of freedom, greatly reducing hysteresis, which is common in piezoelectric actuators. The system is designed to operate in open loop using a lookup table keyed to the Nasmyth rotator angle for flexure control. Here, the optomechanical design of the stage, electrical control system, and current performance results from early prototype efforts are presented and discussed.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑