协调安全与速度:一种人机方法以增强FDA的医疗器械审批政策

Harmonizing Safety and Speed: A Human-Algorithm Approach to Enhance the FDA's Medical Device Clearance Policy

Kelley School of Business, Indiana University(印第安纳大学凯利商学院);Harvard Kennedy School, Harvard University(哈佛大学肯尼迪学院);Emerging Health Consulting(Emerging Health咨询公司)

Mohammad Zhalechian, Soroush Saghafian, Omar Robles

AI总结:

本文提出一种人机协同方法,通过数据驱动的审批政策降低医疗器械召回风险并减少监管工作量,提升FDA 510(k)审批流程的安全性和效率。

摘要:

美国食品药品监督管理局(FDA)的510(k)途径允许制造商通过证明与合法上市设备的实质等效性来获得医疗器械批准。然而,这种监管程序固有的模糊性已与许多通过该途径获批的设备的高召回率相关联,引发了重大安全担忧。在本文中,我们开发了一种结合人类与算法的方法,以帮助FDA改进其510(k)医疗器械审批流程,通过降低召回风险和监管工作量。我们首先开发了机器学习方法,以基于提交时可用的信息来估计510(k)医疗器械的召回风险。然后,我们提出了一种数据驱动的审批政策,该政策推荐接受、拒绝或转交至FDA委员会进行深入评估。我们使用了一个独特的超过31,000份提交的数据库进行实证研究,该数据库基于FDA和医疗补助与医疗救助服务(CMS)的数据源构建。与FDA现行做法相比,其召回率为10.3%,正常化工作量衡量值为100%。对我们的政策的保守评估显示,召回率提高了32.9%,工作量减少了40.5%。我们的分析进一步表明,通过避免替换成本,医疗系统每年可节省约17亿美元,相当于美国全年医疗器械支出的1.1%。我们的发现突显了采用整体和数据驱动方法改进FDA当前510(k)途径的价值。

英文摘要:

The United States Food and Drug Administration's (FDA's) 510(k) pathway allows manufacturers to gain medical device approval by demonstrating substantial equivalence to a legally marketed device. However, the inherent ambiguity of this regulatory procedure has been associated with high recall among many devices cleared through this pathway, raising significant safety concerns. In this paper, we develop a combined human-algorithm approach to assist the FDA in improving its 510(k) medical device clearance process by reducing recall risk and regulatory workload. We first develop machine learning methods to estimate the risk of recall of 510(k) medical devices based on the information available at the time of submission. We then propose a data-driven clearance policy that recommends acceptance, rejection, or deferral to FDA's committees for in-depth evaluation. We conduct an empirical study using a unique dataset of over 31,000 submissions that we assembled based on data sources from the FDA and Centers for Medicare and Medicaid Service (CMS). Compared to the FDA's current practice, which has a recall rate of 10.3% and a normalized workload measure of 100%, a conservative evaluation of our policy shows a 32.9% improvement in the recall rate and a 40.5% reduction in the workload. Our analyses further suggest annual cost savings of approximately $1.7 billion for the healthcare system driven by avoided replacement costs, which is equivalent to 1.1% of the entire United States annual medical device expenditure. Our findings highlight the value of a holistic and data-driven approach to improve the FDA's current 510(k) pathway.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑