arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2407.09629physics.med-phphysics.bio-ph
收藏

FEBio FINESSE:一种使用形状强化的开源有限元模拟方法来估计体内心脏瓣膜应变

FEBio FINESSE: An open-source finite element simulation approach to estimate in vivo heart valve strains using shape enforcement

Devin W. Laurence, Patricia M. Sabin, Analise M. Sulentic, Matthew Daemer, Steve A. Maas, Jeffrey A. Weiss, Matthew A. Jolley

AI总结:

本文提出开源方法FEBio FINESSE,在缺乏患者特异性材料属性时通过形状强化使有限元模拟匹配体内图像衍生的瓣膜几何,能高精度估计瓣叶应变,并成功应用于儿科患者病例。

摘要:

有限元模拟是评估健康和疾病患者心脏瓣膜功能的一种极具吸引力的工具;然而,源自3D超声心动图的患者特异性模拟受到若干技术挑战的阻碍。在这项工作中,我们提出了一种开源方法,用于在缺乏患者特异性材料属性、瓣叶厚度和腱索结构的情况下,强制有限元模拟与体内图像衍生的心脏瓣膜几何形状相匹配。我们使用涵盖广泛模型复杂度的三个合成测试用例评估了FEBio带形状强化的有限元模拟(FINESSE)。我们的结果表明,FINESSE不仅可以强制有限元模拟匹配图像衍生的表面,还可以在+/- 0.03应变的误差范围内估计第一主瓣叶应变。FINESSE的关键注意事项包括:(i) 适当定义用户自定义惩罚项,(ii) 省略瓣叶交界处以改善模拟收敛性,以及(iii) 通过规定瓣叶游离缘运动或腱索模拟力来模拟腱索行为。随后,我们使用FINESSE估计了三名儿科患者的体内瓣膜行为和瓣叶应变。在所有三个病例中,FINESSE成功匹配了目标表面,中值误差等于或小于最小体素尺寸。进一步分析揭示了特定于瓣膜的发现,例如一名患有HLHS的2天大患者的三尖瓣瓣叶应变大于两名13岁患者的瓣叶应变。这一开源流程的开发将使未来的研究能够开始将体内瓣叶力学与患者预后联系起来。

英文摘要:

Finite element simulations are an enticing tool to evaluate heart valve function in healthy and diseased patients; however, patient-specific simulations derived from 3D echocardiography are hampered by several technical challenges. In this work, we present an open-source method to enforce matching between finite element simulations and in vivo image-derived heart valve geometry in the absence of patient-specific material properties, leaflet thickness, and chordae tendineae structures. We evaluate FEBio Finite Element Simulations with Shape Enforcement (FINESSE) using three synthetic test cases covering a wide range of model complexity. Our results suggest that FINESSE can be used to not only enforce finite element simulations to match an image-derived surface, but to also estimate the first principal leaflet strains within +/- 0.03 strain. Key FINESSE considerations include: (i) appropriately defining the user-defined penalty, (ii) omitting the leaflet commissures to improve simulation convergence, and (iii) emulating the chordae tendineae behavior via prescribed leaflet free edge motion or a chordae emulating force. We then use FINESSE to estimate the in vivo valve behavior and leaflet strains for three pediatric patients. In all three cases, FINESSE successfully matched the target surface with median errors similar to or less than the smallest voxel dimension. Further analysis revealed valve-specific findings, such as the tricuspid valve leaflet strains of a 2-day old patient with HLHS being larger than those of two 13-year old patients. The development of this open source pipeline will enable future studies to begin linking in vivo leaflet mechanics with patient outcomes

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑