arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2406.20058astro-ph.CO
收藏

基于21 cm信号三维Minkowski泛函的再电离参数推断

Reionization Parameter Inference from 3D Minkowski Functionals of the 21 cm Signals

Kangning Diao, Zhaoting Chen, Xuelei Chen, Yi Mao

AI总结:

本研究探究利用21 cm亮温度场的Minkowski泛函约束再电离参数,发现SKA-Low的MF测量可区分再电离模型、给出无偏参数估计,联合功率谱可将约束精度提升最高30%,为未来21 cm观测数据分析提供了新工具。

摘要:

Minkowski泛函(MFs)是一类拓扑汇总统计量,已成为提取非高斯信息的有力工具。本文探究了利用再电离时期(EoR)21 cm亮温度场的MFs约束再电离参数的前景。我们对来自氢再电离时期阵列(HERA)、平方公里阵列(SKA)等射电干涉阵实验的模拟观测施加了热噪声、综合波束、前景规避等真实效应。研究表明,通过SKA-Low测量的21 cm信号的MFs可用于区分不同的再电离模型,而类HERA阵列的MF测量无法达到足够的精度。我们进一步采用基于正向建模的标准MCMC分析进行参数推断,预测了MF测量约束再电离参数的精度。结果发现,对于SKA-Low观测,MFs可给出再电离参数的无偏估计,精度与功率谱(PS)分析相当。此外,与仅使用PS的约束相比,联合使用MFs和PS的约束精度最高可提升30%。不过,若因强前景规避导致EoR窗口缩小,约束精度会有所下降。本文分析证明,MFs作为一类汇总统计量,能够从21 cm EoR场中提取与两点统计量互补的信息,这为将MFs纳入未来21 cm观测的数据分析提供了有力依据。

英文摘要:

The Minkowski Functionals (MFs), a set of topological summary statistics, have emerged as a powerful tool for extracting non-Gaussian information. We investigate the prospect of constraining the reionization parameters using the MFs of the 21 cm brightness temperature field from the epoch of reionization (EoR). Realistic effects, including thermal noise, synthesized beam, and foreground avoidance, are applied to the mock observations from the radio interferometric array experiments such as the Hydrogen Epoch of Reionization Array (HERA) and the Square Kilometre Array (SKA). We demonstrate that the MFs of the 21 cm signal measured with SKA-Low can be used to distinguish different reionization models, whereas the MF measurement with a HERA-like array cannot be made accurately enough. We further forecast the accuracies with which the MF measurements can place constraints on reionization parameters, using the standard MCMC analysis for parameter inference based on forward modeling. We find that for SKA-Low observation, MFs provide unbiased estimations of the reionization parameters with accuracies comparable to the power spectrum (PS) analysis. Furthermore, joint constraints using both MFs and PS can improve the constraint accuracies by up to $30\%$ compared to those with the PS alone. Nevertheless, the constraint accuracies can be degraded if the EoR window is shrunk with strong foreground avoidance. Our analysis demonstrates the promise of MFs as a set of summary statistics that extract complementary information from the 21 cm EoR field to the two-point statistics, which suggests a strong motivation for incorporating the MFs into the data analysis of future 21 cm observations.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑