arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2406.19582physics.geo-ph
收藏

模块化摇摆剪力墙抗震韧性结构综述与分析

Overview and Analysis of Seismic Resilient Structures with Modular Rocking Shear Walls

Mehrdad Aghagholizadeh

AI总结:

本文综述模块化摇摆剪力墙的抗震性能,并通过9层和20层框架的OpenSees数值案例表明,增设摇摆剪力墙可使第一振型主导、层间位移角均匀分布,从而避免薄弱层失效。

摘要:

城市多高层建筑的高入住率,加上当前的安全关切,必然促使对性能目标进行重新评估。鉴于大地震后已记录到的显著地震破坏和薄弱层失效实例,本文研究了可在基础之上自由摇摆的模块化剪力墙的使用。本文首先对柱和剪力墙等摇摆构件的分析提供了全面背景。然后讨论了摇摆剪力墙的不同配置。接下来,本文利用OpenSees对9层和20层抗弯框架进行了两个数值案例研究。在多种地震激励下,对两种结构在有和没有模块化摇摆墙情况下的楼层位移和层间位移角进行了比较。结果表明,增加摇摆剪力墙使框架的第一振型成为主导,从而强制实现层间位移角的均匀分布,避免薄弱层失效。

英文摘要:

The high occupancy rates in urban multi-story buildings, combined with present safety concerns, necessarily prompt a reassessment of performance goals. Given the notable seismic damage and instances of weak-story failures that have been documented after major earthquakes, this paper studies the use of modular shear walls that are free to rock above their foundation. This paper first provides a comprehensive background in analysis of rocking elements such as columns and shear-walls. Then discusses different configurations of rocking-shear-walls. Next, the paper provides two numerical case studies on 9-story and 20-story moment-resisting frames using OpenSees. The floor displacement and interstory drifts under various earthquake excitations for both structures compared for the cases of with and without modular rocking walls. The result shows that the addition of rocking-shear-wall, makes the first mode of the frame becomes dominant which enforces a uniform distribution of interstory drifts that would avoid a soft-story failure.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑