arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2406.14925eess.IVcs.AI
收藏

从2D实时MRI中提取下颌髁突的3D轨迹

Extraction of 3D trajectories of mandibular condyles from 2D real-time MRI

IADI, Université de Lorraine, U1254 INSERM(洛林大学 IADI 实验室(法国国家健康与医学研究院 U1254 单位));Oral Medicine Department, University Hospital of Reims(兰斯大学医院口腔医学科);CHRU-NANCY, INSERM, Université de Lorraine, CIC, Innovation Technologique(南锡大学区域医院中心、法国国家健康与医学研究院、洛林大学临床创新技术中心);ENT Department, University Hospital of Reims(兰斯大学医院耳鼻喉科)

Karyna Isaieva, Justine Leclère, Guillaume Paillart, Guillaume Drouot, Jacques Felblinger, Xavier Dubernard, Pierre-André Vuissoz

AI总结:

本研究探究从2D实时MRI提取下颌髁突3D轨迹的可行性,采用基于U-Net的分割方法结合解剖标记投影与时间调整,在20名健康受试者上验证了该方法可提取满足临床相关参数评估精度的髁突轨迹。

摘要:

直接从MRI计算下颌髁突的轨迹可提供全面的检查结果,能够同时提取解剖学和运动学细节。本研究旨在探究从2D实时MRI提取3D髁突轨迹的可行性,并评估其精度。研究招募了20名健康受试者,在其做张口和闭口动作时进行实时MRI扫描。研究采用基于U-Net的算法对1个轴位切片和2个矢状位切片进行分割,将所得掩膜的质心基于解剖标记投影到坐标系中,并使用公共投影进行时间维度上的调整。研究通过专门用于评估运动可重复性、头部运动和切片放置对称性的指标,对计算得到的轨迹质量进行了评估。结果显示,轴位切片的分割质量达到良好至优秀水平,但矢状位切片的分割需要进行一些微调;多数情况下运动可重复性处于可接受水平,但头部运动导致轨迹平均偏移1 mm;闭口位时髁突上下方向坐标的平均差异为1.7 mm。尽管精度存在局限性,实时MRI仍可提取出具有足够准确度的髁突轨迹,可用于评估临床相关参数,如髁突位移、轨迹形态和对称性。

英文摘要:

Computing the trajectories of mandibular condyles directly from MRI could provide a comprehensive examination, allowing for the extraction of both anatomical and kinematic details. This study aimed to investigate the feasibility of extracting 3D condylar trajectories from 2D real-time MRI and to assess their precision.Twenty healthy subjects underwent real-time MRI while opening and closing their jaws. One axial and two sagittal slices were segmented using a U-Net-based algorithm. The centers of mass of the resulting masks were projected onto the coordinate system based on anatomical markers and temporally adjusted using a common projection. The quality of the computed trajectories was evaluated using metrics designed to estimate movement reproducibility, head motion, and slice placement symmetry.The segmentation of the axial slices demonstrated good-to-excellent quality; however, the segmentation of the sagittal slices required some fine-tuning. The movement reproducibility was acceptable for most cases; nevertheless, head motion displaced the trajectories by 1 mm on average. The difference in the superior-inferior coordinate of the condyles in the closed jaw position was 1.7 mm on average.Despite limitations in precision, real-time MRI enables the extraction of condylar trajectories with sufficient accuracy for evaluating clinically relevant parameters such as condyle displacement, trajectories aspect, and symmetry.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑