摘要:

在过去十年中,诸如TAVR之类的人工心脏瓣膜介入治疗迅速增加,但与之相关的长期、危及生命的血栓事件并发症仍持续损害患者预后。因此,改进TAVR器械的血栓形成风险分析至关重要。血栓形成性的体外研究通常难以开展。然而,修订后的ISO测试标准将计算测试纳入心血管植入物的血栓形成风险评估。我们提出了一种用于评估人工心脏瓣膜血栓形成风险的流固耦合(FSI)方法。该FSI框架通过Ansys LS-DYNA软件的不可压缩计算流体力学多物理场求解器实现。用于流动分析的数值建模方法通过以下方式得到验证:将台架测试得到的29-mm CoreValve器械流量以及文献中商用TAVR瓣膜的瓣口面积与计算机模拟结果进行比较。通过Ansys EnSight计算植入流场中的虚拟血小板所承受的应力累积(SA),分析血栓形成风险。随后,将集成的FSI-血栓形成方法用于通过两种途径考察TAVR器械的血流动力学和血栓形成风险:1)工程优化;2)临床评估。我们的方法可用于从最初设计阶段到临床环节改善人工瓣膜的抗血栓性能。它实现了无可比拟的器械优化,除了可通过患者特异性建模评估器械性能外,还揭示了可用于降低血栓形成风险的关键TAVR瓣叶设计参数。本工作展示了对TAVR器械进行先进计算机模拟分析的效用,该分析也可用于其他血液再循环器械的血栓形成风险评估。

英文摘要:

Prosthetic heart valve interventions such as TAVR have surged over the past decade, but the associated complication of long-term, life-threatening thrombotic events continues to undermine patient outcomes. Thus, improving thrombogenic risk analysis of TAVR devices is crucial. In vitro studies for thrombogenicity are typically difficult to perform. However, revised ISO testing standards include computational testing for thrombogenic risk assessment of cardiovascular implants. We present a fluid-structure interaction (FSI) approach for assessing thrombogenic risk of prosthetic heart valves. An FSI framework was implemented via the incompressible computational fluid dynamics multi-physics solver of the Ansys LS-DYNA software. The numerical modeling approach for flow analysis was validated by comparing the derived flow rate of the 29-mm CoreValve device from benchtop testing and orifice areas of commercial TAVR valves in the literature to in silico results. Thrombogenic risk was analyzed by computing stress accumulation (SA) on virtual platelets seeded in the flow fields via Ansys EnSight. The integrated FSI-thrombogenicity methodology was subsequently employed to examine hemodynamics and thrombogenic risk of TAVR devices with two approaches: 1) engineering optimization and 2) clinical assessment. Our methodology can be used to improve the thromboresistance of prosthetic valves from the initial design stage to the clinic. It allows for unparalleled optimization of devices, uncovering key TAVR leaflet design parameters that can be used to mitigate thrombogenic risk, in addition to patient-specific modeling to evaluate device performance. This work demonstrates the utility of advanced in silico analysis of TAVR devices that can be utilized for thrombogenic risk assessment of other blood recirculating devices.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑