arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2406.07903eess.SPcs.SYeess.SY
收藏

GAPses: 用于舒适且完全干燥获取和并行超低功耗处理EEG和EOG的多功能智能眼镜

GAPses: Versatile smart glasses for comfortable and fully-dry acquisition and parallel ultra-low-power processing of EEG and EOG

DEI, University of Bologna(博洛尼亚大学电气、电子与信息系统工程系);University of Bologna(博洛尼亚大学)
Sebastian Frey, Mattia Alberto Lucchini, Victor Kartsch, Thorir Mar Ingolfsson, Andrea Helga Bernardi, Michael Segessenmann, Jakub Osieleniec, Simone Benatti, L… 展开作者

Sebastian Frey, Mattia Alberto Lucchini, Victor Kartsch, Thorir Mar Ingolfsson, Andrea Helga Bernardi, Michael Segessenmann, Jakub Osieleniec, Simone Benatti, Luca Benini, Andrea Cossettini

AI总结:

GAPses是一种多功能智能眼镜,用于舒适且完全干燥获取并行超低功耗处理EEG和EOG信号,实现高精度生物识别和眼动分类。

摘要:

最近在头戴式可穿戴技术方面的进步正在革新生物电位测量领域,但将这些技术整合到实用、用户友好的设备中仍然具有挑战性,因为存在设计侵入性、舒适性和数据隐私的问题。为了解决这些挑战,本文提出了GAPses,一种新型的智能眼镜平台,用于无干扰、舒适且安全的EEG和EOG信号获取和处理。我们引入了直接电极-电子接口,使用定制的干燥软电极以提高长时间佩戴的舒适性。一个集成了并行超低功耗RISC-V处理器(GAP9,Greenwaves Technologies)的边缘处理系统,能够对数据进行边缘处理,从而消除通过无线链路持续数据流的需要,提高隐私性,并在恶劣信道条件下提高系统可靠性。我们通过在多个基于EEG的交互任务中验证了所设计原型的广泛适用性,包括α波、稳态视觉诱发电位分析和运动分类。此外,我们还展示了基于EEG的生物识别主体识别任务,其中我们达到了98.87%的灵敏度和99.86%的特异性,仅使用8个EEG通道,边缘处理的每推理能耗仅为121μJ。此外,在基于EOG的眼动分类任务中,我们达到了11类的96.68%的准确率,得到94.78 bit/min的信息传输率,通过降低准确性至81.43%可进一步提高至161.43 bit/min。部署的实现每推理能耗为40μJ,总系统功率仅为12.4 mW,其中仅1.61%用于分类,允许使用75 mAh的小电池连续运行超过22小时。

英文摘要:

Recent advancements in head-mounted wearable technology are revolutionizing the field of biopotential measurement, but the integration of these technologies into practical, user-friendly devices remains challenging due to issues with design intrusiveness, comfort, and data privacy. To address these challenges, this paper presents GAPses, a novel smart glasses platform designed for unobtrusive, comfortable, and secure acquisition and processing of electroencephalography (EEG) and electrooculography (EOG) signals. We introduce a direct electrode-electronics interface with custom dry soft electrodes to enhance comfort for long wear. An integrated parallel ultra-low-power RISC-V processor (GAP9, Greenwaves Technologies) processes data at the edge, thereby eliminating the need for continuous data streaming through a wireless link, enhancing privacy, and increasing system reliability in adverse channel conditions. We demonstrate the broad applicability of the designed prototype through validation in a number of EEG-based interaction tasks, including alpha waves, steady-state visual evoked potential analysis, and motor movement classification. Furthermore, we demonstrate an EEG-based biometric subject recognition task, where we reach a sensitivity and specificity of 98.87% and 99.86% respectively, with only 8 EEG channels and an energy consumption per inference on the edge as low as 121 $μJ$. Moreover, in an EOG-based eye movement classification task, we reach an accuracy of 96.68% on 11 classes, resulting in an information transfer rate of 94.78 bit/min, which can be further increased to 161.43 bit/min by reducing the accuracy to 81.43%. The deployed implementation has an energy consumption of 40 $μJ$ per inference and a total system power of only 12.4 mW, of which only 1.61% is used for classification, allowing for continuous operation of more than 22 h with a small 75 mAh battery.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑