The Associated Volume sampling algorithm as an alternative method for the calculation of ionisation cluster size distributions in computational nanodosimetry
AI总结:
针对计算条件电离簇尺寸分布时 Uniform Sampling 算法效率低的问题,提出 Associated Volume 算法,对比表明 AV-Overlap 在保证准确性的前提下将计算效率提升一至两个数量级。
摘要:
在计算纳米剂量学中,采用 Monte Carlo Track Structure (MCTS) 模拟来计算电离簇尺寸分布 (ICSDs),这对于表征纳米尺度下的混合辐射场至关重要。为此目的常用的 Uniform Sampling (US) 算法,在评估以簇尺寸超过给定 $ν$ 阈值为条件的 ICSDs 时效率低下。本研究针对从 Geant4-DNA 模拟的质子轨迹中计算条件 ICSDs ($ν\ge 1$),探讨了一种更高效的替代方案——Associated Volume (AV) 算法,并将其与 US 方法进行了对比。评估了 AV 算法的两种配置:允许敏感体积重叠(带有 1/$ν$ 校正)的标准 AV-Overlap,以及防止重叠的新型 AV-No Overlap。我们比较了条件 ICSDs、平均簇尺寸 ($M_1$)、互补累积频率 ($k \in [2,7]$ 时的 $F_k$),以及每次运行和每个事件的总执行时间。均值差异超过两个标准差的偏差被视为具有统计学显著性。尽管在 ICSDs、$M_1$ 和 $F_k$ 中观察到了具有统计学显著性的差异,但 AV-Overlap 中的相对差异极少超过 5%,而在 No Overlap 配置中,相对差异范围从 $\lt$ 1% 到在较高 $F_k$ 处约 15% 不等。两种 AV 配置的执行时间均比 US 算法短一到两个数量级。我们的研究结果表明,AV-Overlap 算法可能是计算条件 ICSDs 及衍生纳米剂量学量的首选替代方案,它在计算效率上提供了显著提升,同时不牺牲准确性。
英文摘要:
In computational nanodosimetry, Monte Carlo Track Structure (MCTS) simulations are employed to calculate ionisation cluster size distributions (ICSDs), which are crucial for characterising mixed radiation fields at the nanoscale. The Uniform Sampling (US) algorithm, commonly used for this purpose, is inefficient when evaluating ICSDs conditioned on clusters exceeding a given size $ν$ threshold. This study investigates a more efficient alternative - the Associated Volume (AV) algorithm - against the US approach for computing conditional ICSDs ($ν\ge 1$) from proton tracks simulated with Geant4-DNA. Two configurations of the AV algorithm were evaluated: the standard AV-Overlap, allowing sensitive volumes to overlap (with a 1/$ν$ correction), and the novel AV-No Overlap, which prevents overlap. We compared the conditional ICSDs, mean cluster size ($M_1$), complementary cumulative frequencies ($F_k$ for $k \in [2,7]$), and overall execution time per run and per event. Deviations exceeding two standard deviations of the mean difference were considered statistically significant. Although statistically significant differences in ICSDs, $M_1$ and $F_k$ were observed, the relative differences in the AV-Overlap rarely exceeded 5%, whereas the No Overlap configuration they ranged from $\lt$ 1% to approximately 15% at the higher $F_k$. Both AV configurations achieved execution times one to two orders of magnitude shorter than the US algorithm. Our findings indicate that the AV-Overlap algorithm may be a preferred alternative for calculating conditional ICSDs and derived nanodosimetric quantities, offering a substantial gain in computational efficiency without compromising accuracy.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。