arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2406.03394cs.CV
收藏

用于可变形图像配准的高斯基元

Gaussian Primitives for Deformable Image Registration

Peking University(北京大学);ETH Zurich(苏黎世联邦理工学院)

Jihe Li, Xiang Liu, Fabian Zhang, Xia Li, Xixin Cao, Ye Zhang, Joachim Buhmann

AI总结:

针对可变形图像配准现有方法计算效率低或泛化性差的问题,提出基于3D高斯泼溅的无需训练的GaussianDIR方法,通过稀疏多尺度自适应高斯基元表征形变,在多医学影像数据集上实现精度与效率的双重提升。

摘要:

可变形图像配准(Deformable Image Registration, DIR)是对齐存在解剖变异的医学图像的关键技术,可为疾病追踪、放疗规划等应用提供支持。经典迭代方法与深度学习方法虽已在DIR领域取得成效,但常受计算效率低下或泛化性差的问题制约。本文提出GaussianDIR,这是一种受3D高斯泼溅启发的、针对特定病例优化的新型DIR方法。总体而言,GaussianDIR通过一组稀疏的可移动柔性高斯基元表征图像形变,每个基元由中心位置、协方差和局部刚性变换定义。这种紧凑且显式的表征方式可降低噪声与计算开销,同时提升可解释性。此外,单个体素的运动通过融合邻近高斯基元的局部刚性变换得到,借此GaussianDIR可同时兼顾全局平滑性与局部刚性,并减轻计算负担。为应对不同程度的形变复杂度,GaussianDIR还集成了自适应密度控制机制,可动态调整高斯基元的密度。另外,我们采用多尺度高斯基元同时捕捉粗粒度与细粒度形变,减少优化陷入局部极小值的情况。在脑部MRI、肺部CT和心脏MRI数据集上的实验结果表明,GaussianDIR在准确性和效率上均优于现有DIR方法,凸显了其临床应用潜力。最后,作为一种无需训练的方法,它打破了迭代方法天生速度慢的刻板印象,也突破了泛化性差的局限。

英文摘要:

Deformable Image Registration (DIR) is essential for aligning medical images that exhibit anatomical variations, facilitating applications such as disease tracking and radiotherapy planning. While classical iterative methods and deep learning approaches have achieved success in DIR, they are often hindered by computational inefficiency or poor generalization. In this paper, we introduce GaussianDIR, a novel, case-specific optimization DIR method inspired by 3D Gaussian splatting. In general, GaussianDIR represents image deformations using a sparse set of mobile and flexible Gaussian primitives, each defined by a center position, covariance, and local rigid transformation. This compact and explicit representation reduces noise and computational overhead while improving interpretability. Furthermore, the movement of individual voxel is derived via blending the local rigid transformation of the neighboring Gaussian primitives. By this, GaussianDIR captures both global smoothness and local rigidity as well as reduces the computational burden. To address varying levels of deformation complexity, GaussianDIR also integrates an adaptive density control mechanism that dynamically adjusts the density of Gaussian primitives. Additionally, we employ multi-scale Gaussian primitives to capture both coarse and fine deformations, reducing optimization to local minima. Experimental results on brain MRI, lung CT, and cardiac MRI datasets demonstrate that GaussianDIR outperforms existing DIR methods in both accuracy and efficiency, highlighting its potential for clinical applications. Finally, as a training-free approach, it challenges the stereotype that iterative methods are inherently slow and transcend the limitations of poor generalization.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑