利用Rydberg原子传感器对ULF、VLF和LF场进行高灵敏度测量
High sensitivity measurement of ULF, VLF and LF fields with Rydberg-atom sensor
AI总结:
本文通过内置平行电极的Cs蒸气池并优化DC场,使Rydberg原子传感器在ULF、VLF和LF频段实现优于1 cm偶极天线的高灵敏度电场测量。
摘要:
频率低于兆赫兹的场对于基于Rydberg原子的测量具有挑战性,这是由吸附在容器内表面的碱金属原子所引起的低频电场屏蔽效应造成的。本文在一个内置平行电极的Cs蒸气池中研究了ULF、VLF和LF频段的电场测量。通过优化所施加的DC场,我们基于Rydberg原子传感器实现了对1 kHz、10 kHz和100 kHz频率电场的高灵敏探测,最小电场强度分别降至18.0 μV/cm、6.9 μV/cm和3.0 μV/cm。对于ULF、VLF和LF场,相应灵敏度为5.7 μV/cm/√Hz、2.2 μV/cm/√Hz和0.95 μV/cm/√Hz,优于1 cm偶极天线。此外,Rydberg原子传感器的线性动态范围超过50 dB。本工作展示了在ULF、VLF和LF场中利用原子传感技术实现更多应用的潜力。
英文摘要:
Fields with frequencies below megahertz are challenging for Rydberg-atom-based measurements, due to the low-frequency electric field screening effect that is caused by the alkali-metal atoms adsorbed on the inner surface of the container. In this paper, we investigate on electric fields measurements in the ULF, VLF and LF bands in a Cs vapor cell with built-in parallel electrodes. With optimization of the applied DC field, we achieve high-sensitive detection of the electric field at frequencies of 1kHz, 10kHz and 100kHz based on Rydberg-atom sensor, with the minimum electric field strength down to 18.0μV/cm, 6.9μV/cm and 3.0μV/cm, respectively. The corresponding sensitivity is 5.7 μV/cm/{\sqrt{Hz}}, 2.2μV/cm/{\sqrt{Hz}} and 0.95μV/cm/{\sqrt{Hz}} for ULF, VLF and LF fields, which is better than 1-cm dipole antenna. Besides, the linear dynamic range of Rydberg-atom sensor is over 50 dB. This work presents the potential to enable more applications that utilize atomic sensing technology in ULF, VLF and LF fields.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。