一种作为治疗补充的可穿戴反重力装置未能改善慢性卒中患者的手臂功能:一项随机试验
A wearable anti-gravity supplement to therapy does not improve arm function in chronic stroke: a randomized trial
AI总结:
本随机试验评估可穿戴 ExoNET 反重力治疗对慢性卒中患者的安全性、可行性与疗效,发现其安全可行并可短期改善 Box and Blocks,但相较对照未显著改善 ARAT 等多数临床指标。
摘要:
背景:重力会干扰卒中后轻偏瘫患者的手臂运动能力。降低其影响可实现有效练习,从而促进恢复。然而,目前缺乏适合在临床多种治疗活动中进行个性化使用的可穿戴设备。目的:在本研究中,我们调查了卒中后参与者使用 ExoNET 设备进行反重力治疗的安全性、可行性和疗效。方法:20名慢性卒中幸存者佩戴 ExoNET 接受6次、每次45分钟的作业治疗,并被随机分入治疗组(ExoNET 调至重力支持模式)或对照组(ExoNET 调至松弛状态)。由设盲评估者在基线、治疗后和6周随访时评估临床结局。研究还评估了动力学、运动学和患者体验结局。结果:混合效应模型显示,治疗组在干预后的 Box and Blocks 评分上有显著改善(效应量:2.1,p=.04)。治疗组与对照组之间在 ARAT 评分和其他临床指标上未发现显著效应。直接动力学效应显示,自由探索期间肌肉活动显著降低,效应量为(-7.12%,p<.005)。未发现显著的纵向动力学或运动学趋势。受试者反馈表明,其对反重力治疗总体持积极看法。结论:使用 ExoNET 进行反重力治疗是一种安全且可行的卒中后康复治疗方法。该设备提供了反重力作用力,且不妨碍关节活动范围;反重力治疗的临床指标显示粗大手部灵活性有所改善。需要进一步研究以探索其在更广泛临床指标中的潜在获益。
英文摘要:
Background: Gravity confounds arm movement ability in post-stroke hemiparesis. Reducing its influence allows effective practice leading to recovery. Yet, there is a scarcity of wearable devices suitable for personalized use across diverse therapeutic activities in the clinic. Objective: In this study, we investigated the safety, feasibility, and efficacy of anti-gravity therapy using the ExoNET device in post-stroke participants. Methods: Twenty chronic stroke survivors underwent six, 45-minute occupational therapy sessions while wearing the ExoNET, randomized into either the treatment (ExoNET tuned to gravity-support) or control group (ExoNET tuned to slack condition). Clinical outcomes were evaluated by a blinded-rater at baseline, post, and six-week follow-up sessions. Kinetic, kinematic, and patient experience outcomes were also assessed. Results: Mixed-effect models showed a significant improvement in Box and Blocks scores in the post-intervention session for the treatment group (effect size: 2.1, p = .04). No significant effects were found between the treatment and control groups for ARAT scores and other clinical metrics. Direct kinetic effects revealed a significant reduction in muscle activity during free exploration with an effect size of (-7.12%, p< 005). There were no significant longitudinal kinetic or kinematic trends. Subject feedback suggested a generally positive perception of the anti-gravity therapy. Conclusions: Anti-gravity therapy with the ExoNET is a safe and feasible treatment for post-stroke rehabilitation. The device provided anti-gravity forces, did not encumber range of motion, and clinical metrics of anti-gravity therapy demonstrated improvements in gross manual dexterity. Further research is required to explore potential benefits in broader clinical metrics.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。