使用深度学习和影像组学技术检测胰周水肿

Detection of Peri-Pancreatic Edema using Deep Learning and Radiomics Techniques

Northwestern University(西北大学);Indiana University(印第安纳大学);National Cancer Institute(国家癌症研究所)

Ziliang Hong, Debesh Jha, Koushik Biswas, Zheyuan Zhang, Yury Velichko, Cemal Yazici, Temel Tirkes, Amir Borhani, Baris Turkbey, Alpay Medetalibeyoglu, Gorkem Durak, Ulas Bagci

AI总结:

本研究提出包含255名患者的CT数据集,利用LinTransUNet分割胰腺,并结合深度学习与影像组学XGBoost分类器检测胰周水肿,发现Swin-Tiny召回率最高,XGBoost可作为快速辅助诊断工具。

摘要:

识别胰周水肿是判断疾病进展和预后的关键指标,这凸显了在胰腺炎诊断和管理中准确检测和评估的迫切需求。本研究引入了一个全新的CT数据集,该数据集来源于255名胰腺疾病患者,包含标注的胰腺分割掩码以及相应的胰周水肿病情诊断标签。利用这一新数据集,我们首先评估了LinTransUNet模型(一种基于线性Transformer的分割算法)从CT影像数据中准确分割胰腺的有效性。随后,我们使用分割出的胰腺区域结合两种不同的机器学习分类器来识别胰周水肿的存在:基于深度学习的模型和基于影像组学的极限梯度提升(XGBoost)。LinTransUNet取得了令人满意的结果,Dice系数达到80.85%,mIoU为68.73%。在用于胰周水肿检测的九个基准分类模型中,Swin-Tiny transformer模型表现出最高的召回率(98.85±0.42)和精确率(98.38±0.17)。相比之下,基于影像组学的XGBoost模型达到了79.61±4.04的准确率和91.05±3.28的召回率,鉴于其快速的处理速度和较短的训练时间,展示了其作为辅助诊断工具的潜力。我们的代码可在https://github.com/NUBagciLab/Peri-Pancreatic-Edema-Detection获取。

英文摘要:

Identifying peri-pancreatic edema is a pivotal indicator for identifying disease progression and prognosis, emphasizing the critical need for accurate detection and assessment in pancreatitis diagnosis and management. This study \textit{introduces a novel CT dataset sourced from 255 patients with pancreatic diseases, featuring annotated pancreas segmentation masks and corresponding diagnostic labels for peri-pancreatic edema condition}. With the novel dataset, we first evaluate the efficacy of the \textit{LinTransUNet} model, a linear Transformer based segmentation algorithm, to segment the pancreas accurately from CT imaging data. Then, we use segmented pancreas regions with two distinctive machine learning classifiers to identify existence of peri-pancreatic edema: deep learning-based models and a radiomics-based eXtreme Gradient Boosting (XGBoost). The LinTransUNet achieved promising results, with a dice coefficient of 80.85\%, and mIoU of 68.73\%. Among the nine benchmarked classification models for peri-pancreatic edema detection, \textit{Swin-Tiny} transformer model demonstrated the highest recall of $98.85 \pm 0.42$ and precision of $98.38\pm 0.17$. Comparatively, the radiomics-based XGBoost model achieved an accuracy of $79.61\pm4.04$ and recall of $91.05\pm3.28$, showcasing its potential as a supplementary diagnostic tool given its rapid processing speed and reduced training time. Our code is available \url{https://github.com/NUBagciLab/Peri-Pancreatic-Edema-Detection}.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑