arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2404.07594cs.CVcs.LGcs.RO
收藏

基于多侧解码器分支的弱监督学习用于机器人辅助心血管导管插入术的工具分割

Weakly-Supervised Learning via Multi-Lateral Decoder Branching for Tool Segmentation in Robot-Assisted Cardiovascular Catheterization

Olatunji Mumini Omisore, Toluwanimi Akinyemi, Anh Nguyen, Lei Wang

AI总结:

针对机器人辅助心血管导管术工具分割中全监督标签成本高的问题,提出含多侧分支解码器的弱监督方法,通过多扰动伪标签扩充部分标注数据,性能接近全监督模型且优于现有弱监督方法,支持临床应用。

摘要:

机器人辅助导管插入术因其在治疗心血管疾病方面的潜力而备受关注。然而,推进外科医生-机器人协作仍需进一步研究,尤其是在任务特定的自动化方面。例如,自动化工具分割可帮助外科医生在心脏手术期间可视化和跟踪血管内工具。虽然基于学习的模型已展现出最先进的分割性能,但为全监督方法生成真实标签既费力耗时又成本高昂。本研究提出一种带有多侧伪标签的弱监督学习方法,用于心血管血管造影数据集的工具分割。该方法采用改进的U-Net架构,包含一个编码器和多个侧向分支解码器。解码器在不同扰动下生成多样的伪标签,扩充可用的部分标签。伪标签通过混合损失函数自生成,且解码器间具有共享一致性。弱监督模型采用端到端训练,并使用来自三种心血管导管插入术的部分标注血管造影数据进行验证。验证结果表明,该模型的性能可接近全监督模型。此外,所提出的弱监督多侧方法优于三种知名的弱监督学习方法,在三个血管造影数据集上均提供最高的分割性能。大量消融研究证实了模型在不同参数下的一致性能。最后,该模型被应用于机器人辅助导管插入术实验中的工具分割,为导丝和导管提供了具有高连通性指数的增强可视化,每帧平均处理时间为35毫秒。

英文摘要:

Robot-assisted catheterization has garnered a good attention for its potentials in treating cardiovascular diseases. However, advancing surgeon-robot collaboration still requires further research, particularly on task-specific automation. For instance, automated tool segmentation can assist surgeons in visualizing and tracking of endovascular tools during cardiac procedures. While learning-based models have demonstrated state-of-the-art segmentation performances, generating ground-truth labels for fully-supervised methods is both labor-intensive time consuming, and costly. In this study, we propose a weakly-supervised learning method with multi-lateral pseudo labeling for tool segmentation in cardiovascular angiogram datasets. The method utilizes a modified U-Net architecture featuring one encoder and multiple laterally branched decoders. The decoders generate diverse pseudo labels under different perturbations, augmenting available partial labels. The pseudo labels are self-generated using a mixed loss function with shared consistency across the decoders. The weakly-supervised model was trained end-to-end and validated using partially annotated angiogram data from three cardiovascular catheterization procedures. Validation results show that the model could perform closer to fully-supervised models. Also, the proposed weakly-supervised multi-lateral method outperforms three well known methods used for weakly-supervised learning, offering the highest segmentation performance across the three angiogram datasets. Furthermore, numerous ablation studies confirmed the model's consistent performance under different parameters. Finally, the model was applied for tool segmentation in a robot-assisted catheterization experiments. The model enhanced visualization with high connectivity indices for guidewire and catheter, and a mean processing time of 35 ms per frame.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑