Framework to generate perfusion map from CT and CTA images in patients with acute ischemic stroke: A longitudinal and cross-sectional study
School of Biomedical Engineering and Imaging Sciences, King’s College London(伦敦国王学院生物医学工程与影像科学学院);University of Bern(伯尔尼大学);Inselspital, Bern University Hospital(伯尔尼大学医院因塞尔spital);King’s College Hospital NHS Foundation Trust(国王学院医院NHS基金会信托);University College London(伦敦大学学院)
Chayanin Tangwiriyasakul, Pedro Borges, Stefano Moriconi, Paul Wright, Yee-Haur Mah, James Teo, Parashkev Nachev, Sebastien Ourselin, M. Jorge Cardoso
备注:
Accepted and presented in SWITCH2023: Stroke Workshop on Imaging and Treatment CHallenges (MICCAI 2023, Vancouver Canada)
Stroke is a leading cause of disability and death. Effective treatment decisions require early and informative vascular imaging. 4D perfusion imaging is ideal but rarely available within the first hour after stroke, whereas plain CT and CTA usually are. Hence, we propose a framework to extract a predicted perfusion map (PPM) derived from CT and CTA images. In all eighteen patients, we found significantly high spatial similarity (with average Spearman's correlation = 0.7893) between our predicted perfusion map (PPM) and the T-max map derived from 4D-CTP. Voxelwise correlations between the PPM and National Institutes of Health Stroke Scale (NIHSS) subscores for L/R hand motor, gaze, and language on a large cohort of 2,110 subjects reliably mapped symptoms to expected infarct locations. Therefore our PPM could serve as an alternative for 4D perfusion imaging, if the latter is unavailable, to investigate blood perfusion in the first hours after hospital admission.
Automatic Ischemic Stroke Lesion Segmentation from Computed Tomography Perfusion Images by Image Synthesis and Attention-Based Deep Neural Networks
University of Electronic Science and Technology of China(电子科技大学);SenseTime Research(商汤科技研究院);Huashan Hospital, Fudan University(复旦大学附属华山医院);Fudan University(复旦大学);Jing’an District Centre Hospital of Shanghai(上海市静安区中心医院)
Synthetic Perfusion Maps: Imaging Perfusion Deficits in DSC-MRI with Deep Learning
University of Bern(伯尔尼大学);Department of Neurology, Inselspital, University of Bern(伯尔尼大学 Inselspital 神经科);Department of Neurology, University of California Los Angeles (UCLA)(加州大学洛杉矶分校(UCLA)神经科);Support Center for Advanced Neuroimaging, Institute for Diagnostic and Interventional Neuroradiology, Inselspital, University of Bern(伯尔尼大学 Inselspital 诊断与介入神经放射学研究所高级神经影像支持中心)
Reconstructing Quantitative Cerebral Perfusion Images Directly From Measured Sinogram Data Acquired Using C-arm Cone-Beam CT
Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences(中国科学院深圳先进技术研究院);Southeast University(东南大学);United Imaging Healthcare Limited Company(联影医疗科技股份有限公司)
Point Cloud Registration for Fusion between SPECT MPI and CTA Images
School of Computer Science and Artificial Intelligence, Zhengzhou University of Light Industry(郑州轻工业大学计算机科学与人工智能学院);School of Automation, Xi’an University of Posts and Telecommunications(西安邮电大学自动化学院);Xi'an Key Laboratory of Advanced Control and Intelligent Process(西安先进控制与智能过程重点实验室);School of Information Management and Engineering, Shanghai University of Finance and Economics(上海财经大学信息管理与工程学院);Department of Computer Science, Kennesaw State University(肯尼斯州立大学计算机科学系);Department of Cardiology, The First Affiliated Hospital of Nanjing Medical University(南京医科大学第一附属医院心内科);Department of Applied Computing, Michigan Technological University(密歇根技术大学应用计算系);Center for Biocomputing and Digital Health, Institute of Computing and Cybersystems, and Health Research Institute, Michigan Technological University(密歇根技术大学生物计算与数字健康中心、计算与网络系统研究所及健康研究机构)
Self-supervised Dynamic CT Perfusion Image Denoising with Deep Neural Networks
Center for Advanced Medical Computing and Analysis(高级医学计算与分析中心);Gordon Center for Medical Imaging(戈登医学成像中心);Massachusetts General Hospital(麻省总医院);Harvard Medical School(哈佛医学院)
DSA-NRP: No-Reflow Prediction from Angiographic Perfusion Dynamics in Stroke EVT
Department of Electrical and Computer Engineering, UCLA(电气与计算机工程系,加州大学洛杉矶分校);Medical Informatics, UCLA(医学信息学,加州大学洛杉矶分校);Department of Radiological Sciences, UCLA(放射科学系,加州大学洛杉矶分校);Department of Radiology, UC San Francisco(放射科,旧金山大学医学院);Department of Bioengineering, UCLA(生物工程系,加州大学洛杉矶分校);Department of Pathology and Laboratory Medicine, UCLA(病理学与实验室医学系,加州大学洛杉矶分校)
Lesion-Aware Post-Training of Latent Diffusion Models for Synthesizing Diffusion MRI from CT Perfusion
College of Medicine, Seoul National University, Seoul, Republic of Korea(首尔国立大学医学院);Department of Radiology, Seoul National University Hospital(首尔国立大学医院放射科);Department of Biomedical Sciences, Seoul National University(首尔国立大学生物医学科学系)
Ischemic Stroke Segmentation and Net Water Uptake Quantification on Multicenter Non-Contrast CT Using Supervised Target-Domain Adaptation
University Medical Center Hamburg-Eppendorf(汉堡-埃彭多夫大学医学中心);University Hospital Marburg(马尔堡大学医院);Massachusetts General Hospital(麻省总医院);Harvard Medical School(哈佛医学院);HELIOS Medical Center Schwerin(HELIOS什未林医疗中心);MSH Medical School Hamburg(汉堡MSH医学院);MSH Research, Development and Innovation GmbH(MSH研究开发与创新有限公司);MSH Medical University of Applied Sciences and Medical University(MSH应用科学医科大学与医科大学)
Point cloud-based registration and image fusion between cardiac SPECT MPI and CTA
Xi’an University of Posts and Telecommunications(西安邮电大学);Nanjing Medical University(南京医科大学);The First Affiliated Hospital of Nanjing Medical University(南京医科大学第一附属医院);The First Affiliated Hospital of Xi’an Jiaotong University(西安交通大学第一附属医院);Kennesaw State University(肯尼索州立大学);Michigan Technological University(密歇根理工大学)
Department of Electrical Engineering and Computer Science, University of Stavanger(斯瓦尔巴大学电子工程与计算机科学系);Stavanger Medical Imaging Laboratory, Stavanger University, Hospital(斯塔万格医学影像实验室,斯塔万格大学医院)