arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2403.14489cs.CV
收藏

对抗鲁棒的基于图的WSI学习

Adversary-Robust Graph-Based Learning of WSIs

Marquette University(马凯特大学);Northshore Pathologists, S.C.(北岸病理医生有限责任公司)

Saba Heidari Gheshlaghi, Milan Aryal, Nasim Yahyasoltani, Masoud Ganji

AI总结:

本研究提出一种基于图的深度学习模型,通过GNN提取WSIs特征并结合去噪模块与transformer,有效提升了癌症Gleason分级系统抵御图像及图层面对抗攻击的鲁棒性与诊断准确率。

摘要:

增强深度学习模型抵御对抗攻击的鲁棒性至关重要,特别是在医疗保健等关键领域,巨大的经济利益加剧了此类攻击的风险。Whole slide images (WSIs) 是装载在玻片上的组织样本的高分辨率数字化版本,使用精密成像设备扫描而成。由于WSIs的千兆像素尺寸和多分辨率存储格式,其数字分析面临独特的挑战。在本研究中,我们旨在提高癌症Gleason分级分类系统抵御对抗攻击的鲁棒性,解决图像和图层面的挑战。就所提出的算法而言,我们开发了一种新颖的基于图的模型,利用GNN从WSIs的图表示中提取特征。结合去噪模块和池化层来管理对抗攻击对WSIs的影响。最后通过transformer模块基于处理后的数据对前列腺癌的各个等级进行分类。为评估所提方法的有效性,我们使用两种场景进行了对比分析。首先,在未暴露于任何攻击的WSIs上训练并测试不含去噪器的模型。随后,在图像或图层面引入一系列攻击,并通过所提出的网络进行处理。从准确率和kappa分数方面评估模型性能。对比结果显示,癌症诊断准确率有显著提高,突显了所提方法在处理医学成像中对抗挑战时的鲁棒性和高效性。

英文摘要:

Enhancing the robustness of deep learning models against adversarial attacks is crucial, especially in critical domains like healthcare where significant financial interests heighten the risk of such attacks. Whole slide images (WSIs) are high-resolution, digitized versions of tissue samples mounted on glass slides, scanned using sophisticated imaging equipment. The digital analysis of WSIs presents unique challenges due to their gigapixel size and multi-resolution storage format. In this work, we aim at improving the robustness of cancer Gleason grading classification systems against adversarial attacks, addressing challenges at both the image and graph levels. As regards the proposed algorithm, we develop a novel and innovative graph-based model which utilizes GNN to extract features from the graph representation of WSIs. A denoising module, along with a pooling layer is incorporated to manage the impact of adversarial attacks on the WSIs. The process concludes with a transformer module that classifies various grades of prostate cancer based on the processed data. To assess the effectiveness of the proposed method, we conducted a comparative analysis using two scenarios. Initially, we trained and tested the model without the denoiser using WSIs that had not been exposed to any attack. We then introduced a range of attacks at either the image or graph level and processed them through the proposed network. The performance of the model was evaluated in terms of accuracy and kappa scores. The results from this comparison showed a significant improvement in cancer diagnosis accuracy, highlighting the robustness and efficiency of the proposed method in handling adversarial challenges in the context of medical imaging.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑