本研究评估了在颅脑MRI上利用预检查(诊断前MRI)改善自动化转移瘤检测,发现仅纳入对比增强T1加权图像的双时间点方法(CNNdual_ce)达到最高性能(敏感性73%,F1=36%),并显著减少假阳性,而额外序列无益。

摘要:

材料与方法:首先,评估了一种双时间点方法,其中CNN被提供最初显示新发转移瘤(诊断MRI)以及诊断前MRI的MRI序列:仅纳入对比增强T1加权图像(CNNdual_ce)与同时纳入两个时间点的平扫T1加权图像、T2加权图像和FLAIR序列(CNNdual_all)进行比较。其次,将结果与相应的单时间点方法进行比较,其中CNN仅被提供诊断MRI的相应序列。通过5折交叉验证计算逐病例的诊断性能参数。结果:共纳入94例病例,包含494个转移瘤。总体而言,最高的诊断性能通过仅纳入诊断和诊断前MRI的对比增强T1加权图像实现(CNNdual_ce,敏感性=73%,阳性预测值=25%,F1分数=36%)。与纳入对比增强T1加权图像以外的更多序列相比,仅使用对比增强T1加权图像作为输入导致显著更少的假阳性(FP)(CNNdual_ce/CNNdual_all的FP=5/7,P<1e-5)。对比增强双时间点与单时间点方法的比较显示,排除诊断前MRI显著增加FP(CNNdual_ce/CNNce的FP=5/10,P<1e-9)。仅使用平扫序列的方法明显逊于提供对比增强序列的CNN。结论:在对比增强T1加权图像上进行自动化转移瘤检测具有高敏感性。由伪影和血管导致的频繁假阳性通过额外纳入诊断前MRI显著减少,但纳入对比增强T1加权图像以外的更多序列并未减少。未来的研究可能探索不同的变化检测架构用于计算机辅助检测。

英文摘要:

Materials and methods: First, a dual-time approach was assessed, for which the CNN was provided sequences of the MRI that initially depicted new MM (diagnosis MRI) as well as of a prediagnosis MRI: inclusion of only contrast-enhanced T1-weighted images (CNNdual_ce) was compared with inclusion of also the native T1-weighted images, T2-weighted images, and FLAIR sequences of both time points (CNNdual_all).Second, results were compared with the corresponding single time approaches, in which the CNN was provided exclusively the respective sequences of the diagnosis MRI.Casewise diagnostic performance parameters were calculated from 5-fold cross-validation. Results: In total, 94 cases with 494 MMs were included. Overall, the highest diagnostic performance was achieved by inclusion of only the contrast-enhanced T1-weighted images of the diagnosis and of a prediagnosis MRI (CNNdual_ce, sensitivity = 73%, PPV = 25%, F1-score = 36%). Using exclusively contrast-enhanced T1-weighted images as input resulted in significantly less false-positives (FPs) compared with inclusion of further sequences beyond contrast-enhanced T1-weighted images (FPs = 5/7 for CNNdual_ce/CNNdual_all, P < 1e-5). Comparison of contrast-enhanced dual and mono time approaches revealed that exclusion of prediagnosis MRI significantly increased FPs (FPs = 5/10 for CNNdual_ce/CNNce, P < 1e-9).Approaches with only native sequences were clearly inferior to CNNs that were provided contrast-enhanced sequences. Conclusions: Automated MM detection on contrast-enhanced T1-weighted images performed with high sensitivity. Frequent FPs due to artifacts and vessels were significantly reduced by additional inclusion of prediagnosis MRI, but not by inclusion of further sequences beyond contrast-enhanced T1-weighted images. Future studies might investigate different change detection architectures for computer-aided detection.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑